RANGE HOOD
REMOTE CONTROL
READ AND SAVE THESE
INSTRUCTIONS
Your Broan BCR1 remote control is a Radio
Frequency (RF) wireless device used to operate
the fan, lights, and delay-off feature on compatible
Broan range hoods. Refer to your hood installation
manual or product specification sheet to ensure
your hood is compatible with Broan model BCR1
remote control.
Unlike Infrared (IR) remotes, which are the most
common, RF remotes are easier to use because
they do not require line of sight, so they do not
have to be aimed directly at the equipment they
are controlling. RF is a very convenient, reliable
method to transmit commands without wires for
the operation of your compatible range hood.
This system will offer exceptional performance
in most cases. Although signals will often travel
great distances, as well as around and through
structures/walls, there are some limitations to the
operating range. See troubleshooting guide on
page 1 regarding these limitations.
CONTROL OPERATION
When a button is depressed on the remote control,
it sends a coded signal to the receiver installed
on a Broan compatible hood, telling it which
function to activate.
LED INDICATOR
LIGHT
DELAY-OFF
Light Button – When the hood lights are OFF,
pressing the light button will turn the hood lights
ON to the lowest setting. Pressing again will index
the lights to the next highest setting. When lights
are at the highest setting, pressing the button again
will turn lights OFF.
Fan Button –
When the hood fan is OFF,
pressing the fan button will turn the hood fan ON
to the lowest setting. Pressing again will index the
fan speed to the next highest setting. When hood
fan is at its highest setting, pressing the button
again will turn fan OFF.
Delay off Button – When hood fan is ON,
pressing the Delay-OFF button will activate the
Delay-OFF feature of the hood. Pressing again will
turn the DELAY-OFF feature OFF. If the hood fan is
OFF, pressing the button will have no effect.
The green LED indicator on the remote will
illuminate to indicate that the function has been
transmitted. An audible "beep" at the hood, and
change in function will indicate that the hood has
received the transmission.
Your Broan remote control comes equipped
with magnetic, non-slip feet. It can be adhered
to a vertical metal/magnetic surface (such as a
refrigerator door) or placed on a horizontal surface.
The RF encoder on your remote control is a fixed
address encoder, meaning the address (security)
code can be changed to another code manually.
There exists a slight possibility of interference from
other RF remote controls (garage door transmitter,
home and car security systems, remote control
paddle fans, other range hoods installed nearby).
To resolve interference issues, the address or
code can be changed (up to 32 independent
address codes) by changing the settings on the
5 position DIP switches on the handheld remote
and compatible range hood.
cases, this will not be necessary. The product is
shipped from the factory (transmitter and receiver)
with DIP address settings set to matching codes
(switch 1 set to ON - switches 2-5 set to OFF). Assuming
there are no interference issues, the user won't need to
change the DIP switch address code settings.
CHANGING SECURITY CODES
Remote (Transmitter)
Open the back cover of the remote by removing
the center screw, and placing a flat screwdriver in
between two halves of the housing to pry apart.
Locate the 5-position DIP switch on the circuit board.
ON
1
2
Using a small insulated screwdriver or other non-
conductive instrument, adjust one or more of the
5 DIP switches to a different position (ON or OFF).
Note that SWITCH "1" was factory-set to the "ON"
position and SWITCHES "2-5" were factory-set
to the "OFF" position. Prior to re-assembling the
remote, carefully note the new DIP switch settings
so the same settings can be used on the hood
(receiver). Carefully reassemble the remote.
Hood (Receiver)
WARNING – TO REDUCE THE RISK OF FIRE,
FAN
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: IF YOU HAVE
QUESTIONS, CONTACT THE MANUFACTURER AT
THE ADDRESS OR TELEPHONE NUMBER LISTED
IN THE WARRANTY. BEFORE SERVICING OR
CLEANING UNIT, SWITCH POWER OFF AT SERVICE
PANEL AND LOCK THE SERVICE DISCONNECTING
MEANS TO PREVENT POWER FROM BEING
SWITCHED
SERVICE DISCONNECTING MEANS CANNOT BE
LOCKED, SECURELY FASTEN A PROMINENT
WARNING DEVICE, SUCH AS A TAG, TO THE
SERVICE PANEL. ELECTRICAL WORK MUST
BE DONE BY A QUALIFIED PERSON(S) IN
ACCORDANCE WITH ALL APPLICABLE CODES
AND STANDARDS.
Locate the 5-position DIP switch on the hood
(usually located on the circuit board) – refer to your
hood installation instruction for additional details
if necessary.
ON
1
2
Using a small insulated screwdriver or other non-
conductive instrument, adjust the DIP switches
to the same settings as the remote control.
Reassemble any parts from hood that were removed
to access the DIP switches.
Note that in most
SWITCH "1"
SHOWN "ON"
SWITCHES "2-5"
3
4
5
SHOWN "OFF"
ON
ACCIDENTALLY.WHEN
THE
SWITCH "1"
SHOWN "ON"
SWITCHES "2-5"
3
4
5
SHOWN "OFF"
MODEL BCR1
Verify the function of the remote control and hood
once DIP switch settings are properly paired. New
settings may be needed if interference issues are
still encountered.
CLEANING AND MAINTENANCE
Clean surfaces with a damp, clean cloth and mild
detergent only.
Do not immerse in water. Your remote is
considered to be "splash-proof", not "waterproof".
Your Broan remote transmitter is a user friendly
device designed for years of trouble free operation.
Under most circumstances it should require only
periodic battery replacement. The transmitter
is powered by a long life A23-style 12V battery
available at most hardware stores or home centers.
The battery on your remote control should last in
excess of 1-year under normal operation.
To change the battery, remove the battery cover
by using a small flat bladed screwdriver to gently
pry open. Remove existing battery utilizing a
small insulated flat bladed screwdriver or other
non-conductive instrument, and discard properly
with consideration to local codes and recycling
guidelines. Install the new battery while ensuring
the "+" side of the battery lines up with the "+"
terminal of the remote. Replace cover.
WARNING – TO PREVENT POSSIBLE SERIOUS
INJURY OR DEATH:
NEVER ALLOW SMALL
CHILDREN NEAR BATTERIES. IF BATTERY IS
SWALLOWED, IMMEDIATELY NOTIFY DOCTOR
Notice: Operation is subject to the following
two conditions: (1) This device may not cause
interference, and (2) this device must accept any
interference that may cause undesired operation of
the device.
TROUBLE SHOOTING GUIDE
Remote
transmitting
signal
illuminates) but hood not receiving
• Ensure hood is powered.
• Battery weak – install new fresh A23-12V battery
• Check the receiver and transmitter dip switches
are set at the same setting.
Transmission Range Short
• Change orientation of remote when activating
• Change
location
of
remote
obstructions
• Battery weak – install new fresh A23-12V battery
Interference
encountered
with
transmitters or receivers
• Change encoder DIP switch settings
Page 1
(green
LED
to
minimize
other
RF

Publicité

loading

Sommaire des Matières pour Broan BCR1

  • Page 1 To resolve interference issues, the address or CLEANING AND MAINTENANCE code can be changed (up to 32 independent Your Broan BCR1 remote control is a Radio address codes) by changing the settings on the Frequency (RF) wireless device used to operate...
  • Page 2 DIP sur la manette de la télécommande et sur la hotte compatible. Veuillez noter NETTOYAGE ET ENTRETIEN Votre télécommande Broan BCR1 est un dispositif sans fil à que, dans le plupart des cas, cela n’est pas nécessaire. radiofréquence (RF) commandant le ventilateur, l’éclairage Le produit est expédié...
  • Page 3 DIP de cinco posiciones en el control remoto de mano y la campana El control remoto BCR1 de Broan es un dispositivo LIMPIEZA Y MANTENIMIENTO compatible. Tome en cuenta que la mayoría de las veces inalámbrico de radiofrecuencia (RF) que se utiliza para operar...
  • Page 4 (b) give the model number and part en vigueur. La présente garantie remplace toutes les autres garanties précédentes. Para tener derecho al servicio de la garantía, usted debe (a) notificar a Broan identification and (c) describe the nature of any defect in the product or Pour vous prévaloir de cette garantie, vous devez (a) aviser Broan-NuTone à...