Airmax Shallow Water Serie Mode D'emploi page 8

Système d'aération
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Maintenance**
Airmax
Aeration Systems are designed for low-maintenance and re-
®
quire minimal scheduled maintenance. Cabinet inlets and outlets should
be kept free of debris and weed growth allowing normal ventilation.
• Always unplug system before performing any maintenance
or troubleshooting.
• Always unplug system and refer servicing to a qualified
electrician when: cord is damaged or frayed, compressor, power
control, compressor fan, or other electrical components are producing
unusual noises or odors.
• Always use parts that are supplied or approved by Airmax
of other parts may result in poor performance and could create a
hazardous situation.
** Local environmental conditions may require more frequent
maintenance.
WARNING: Compressors are equipped with a thermal overload switch.
If temperature becomes high enough to trip the overload, the compres-
sor will shut down. It will then automatically start up when temperature
decreases as long as power is applied.
5. Troubleshooting
IF COMPRESSOR IS NOT OPERATING:
ISSUE
Cabinet fan is not running.
Cabinet fan is running.
IF COMPRESSOR IS OPERATING:
ISSUE
No bubbles at any diffusers.
No bubbles at some diffuser plates.
Large rolling bubbles instead of fine
bubbles at surface above one or more
diffuser plates.
Compressor stops working for periods of
time, then restarts.
Compressor shakes erratically and is
making loud noises.
8
®
, Inc. Use
CHECK
Option 1: Check for power.
Option 2: GFCI circuit tripped.
Option 3: GFCI circuit not tripped.
Check compressor for power.
CHECK
Option 1: No air leaks are audible in cabinet.
Compressor running louder and
possible excessive vibration.
Option 2: Compressor operating normally or
making unusual noises. Exhibits
reduced pressure and/or air flow.
Option 1: Check for leaks at all connections
in line and in cabinet. If none are
audible, carefully spray SMALL
amount of soapy water onto
connections and look for bubbles.
Option 2: Are all flow control valves in
compressor wide open?
Option 3: Valves in cabinet are properly
"balanced" and no leaks
are evident.
Inspect each diffuser plate for malfunction.
Inspect cooling fan for proper function.
Option 1: Check for low voltage while
compressor is running.
Option 2: Check for clogged air filter.
EVERY 3-6 MONTHS – Air Filter: Clean/replace air filter.
Cooling Fan: Check to ensure cooling fan is operating. Hot air should be pulled from
the cabinet, not blowing in.
EVERY 6-12 MONTHS – Maintenance Kit: It is recommended to install a
maintenance kit every 6-12 months to ensure optimum performance.
EVERY 24-36 MONTHS – Membrane Sticks: We recommend inspecting and/
or cleaning the membrane diffuser sticks every 24-36 months, or anytime there is a
reduction in bubbles from the diffuser. To clean, use Airmax® Fountain & Aeration
Cleaner (#530298) and a soft cloth.
LIKELY CAUSE
Compressor and fan are not receiving power.
Damage to electrical cord or low voltage from power
supply.
GFCI malfunction.
Compressor is not receiving power.
LIKELY CAUSE
Compressor air filter is dirty/clogged.
Compressor needs maintenance kit and possibly
new air filter.
Vibration loosened connection or cracked fitting.
Improper "balancing" of diffusers.
Compressor beginning to lose compression and
needs maintenance kit.
Diffuser membrane damaged, diffuser plate fitting
broken or diffuser plate is flipped over.
Compressor over-heating due to bad cooling fan.
Gauge of supply wires to circuit possibly undersized or
cabinet is plugged into extension cord.
Air filter in need of replacement.
Watch the Maintenance Kit
How-To Video at
airmaxeco.com/ShallowWaterSeries
CORRECTION
Open cabinet and ensure the compressor and fan are
plugged into the power outlet.
®
Contact Airmax
or local dealer for electrical
troubleshooting assistance.
Open cabinet and ensure the compressor is plugged into the
power outlet.
CORRECTION
Clean or replace air filter. NEVER re-install wet filter.
®
Contact Airmax
or local dealer with specifications for
maintenance kit. Clean or replace air filter. NEVER re-
install wet filter.
Tighten loose connection or replace cracked fitting
as necessary.
Adjust air flow valves on manifold in cabinet until all diffusers
operate properly. See Section 2. System Installation for
more information.
®
Contact Airmax
or local dealer with compressor
specifications for maintenance kit.
®
Contact Airmax
or local dealer for repair/replacement.
®
Contact Airmax
or local dealer for fan replacement. If
possible, leave top of cabinet open for cooling. Otherwise,
unplug system until fan is replaced.
If gauge of circuit wiring is incorrect, have electrician replace.
NEVER use extension cord to operate system
for continual use.
Clean or replace air filter. NEVER re-install wet filter.
ENGLISH

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Shallow water sw20Shallow water sw40600801

Table des Matières