WATER SOFTENERS DOUBLE 35
B
TEMPO
VOLUME
ORA DI RIG.
GIORNO DI RIG.
VOLUME
VOL. RIMANENTE
ORARIO
PROGRAMMA
AVANZAMENTO
VOLUME/ORA
RIG. MANUALE
RESET
MULT IMODE
BIO COMPURI T YSYSTEM
CALORECLIMA
TECHNICAL FEATURES DOUBLE 35-50-65-85-125
Fittings
Resin
Model
Ø
lt
1 1/4"
35
DOUBLE 35
1 1/4"
50
DOUBLE 50
1 1/4"
65
DOUBLE 65
1 1/2"
85
DOUBLE 85
DOUBLE 125
1 1/2" 125
THE MULTIMODE PLUS VALVE WHICH FITS
THE DOUBLE MODELS CONSISTS MAINLY
OF THE FOLLOWING:
A -
Multimode plus timer with digital
programming
B -
Hydraulic command unit of the
operating pistons including two
small pilot pistons
C -
The valve body including two
housings for the sliding of the two
service pistons
D -
By-pass unit for model
DOUBLE 85-125 is not included
1 -
Programmer
2 -
Cams
3 -
Control piston
4 -
Operating piston
5 -
Upper diffuser
125
÷
A
F
E
Flowrate
Oper.
press.
Med.
Max.
l/h
kg/cm
2
1800
2700
2÷7
2400
3000
2÷7
3500
5500
2÷7
5700
8100
2÷7
7500
10000
2÷7
A 2 4 3
C
C
Salt cont.
Salt
cont. cap.
Max.
mc°F
kg NaCl
kg
210
7
200
275
9,5
200
412
16
300
510
21
300
720
31
300
SUCTION
ASPIRAZION E
B
5
D
SCARIC O
DRAIN
OPERATING DATA
Power
230 V
Ext. transformer
Absorption
Min. pressure
Max. pressure
Min. water temp.
Max. water temp.
DIMENSIONS
A
B
C
D
mm
800
260
1335 1435
900
330
1235 1335
1100
370
1600 1700
1150
400
1900 2000
1150
400
1900 2000
1
ORA DI RIG.
GIORNO DI RIG.
ORARIO
PROGRAMMA
MULT IMODE
BIO COMPURITY SYSTEM
INFEED
Fig. 1
OUTFEED
25
50 Hz
12 V
8 A
2 Kg/cm
2
6 Kg/cm
2
2 °C
40 °C
E
F
530
1050
530
1050
700
1060
700
1060
700
1060
TEMPO
VOLUME
VOL. RIMANENTE
VOLUME
AVANZAMENTO
VOLUME/ORA
RIG. MANUALE
RESET
CALORECLIMA