OPERATION
CHARGING PROCEDURE
NOTE: The battery is not shipped fully charged. It is recommended to fully charge before first
use to ensure that maximum run time can be achieved. This lithium-ion battery will not develop a
memory and may be charged at any time.
Low voltage charging:
If the battery has been stored with little to no charge for a long period of time, the charger will go
into recovery mode, which will take 20 hrs to fully charge the battery. This will enhance the life of
the battery. Once it is fully charged, the next charge will return to standard charging.
1. Plug the charger into an AC power outlet.
2. Insert the battery pack into the charger.
This is a diagnostic charger. The Charger LED Lights will illuminate in specific order to
communicate the current battery status. They are as follows:
False defect note:
When the battery is inserted into the charger and the status LED blinks RED, remove the battery
from the charger for 1 minute, then reinsert. If the status LED blinks GREEN, then the battery
is properly charging. If the status LED is still blinking RED, remove the battery and unplug the
charger for 1 minute. After 1 minute, plug in the charger and reinsert the battery. If the status LED
blinks GREEN, then the battery is properly charging. If the status LED is still blinking RED, the
battery is defective and needs to be replaced.
Fully
Charging
Charged
LED STATUS
Solid Green
Blinking Green
Solid Red
Blinking Red
8
Over
Charging
Temperature
DESCRIPTION
Fully Charged
Charging
Over Temperature
Charging Fault
Fault