When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electric shock and injury to
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE
FOLLOWING:
a)
Use this unit only in the manner intended by the manufacturer.If you have questions,
contact the manufacturer.
b)
Before servicing or cleaning the unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE
FOLLOWING:
a)
Installation work and electrical wiring must be done by qualified person(s) in accordance
with all applicable codes and standards, including fire-related construction.
b)
Sufficient air is needed for proper combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c)
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION:
PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT
VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL
SPACES, OR GARAGES.
d)
Ducted fans must always be vented to the outdoors.
e)
This unit must be grounded.
f)
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
g)
Read all instructions before installing or using range hood.
6728012 Rev. O 4-17
OPERATING MANUAL
AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE ONLY. DO NOT
TO REDUCE THE RISK OF FIRE AND TO
SAVE THESE INSTRUCTIONS
a)
Never leave surface units unattended at high settings. Boil overs cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b)
Always turn hood ON when cooking at high heat or when flambéing food (ie. Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c)
Clean ventilating fans frequently. Grease should not be allowed to accumulate on
fan filter.
d)
Use proper pan size. Always use cookware appropriate for the size of the surface
element.
a)
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off
burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
b)
NEVER PICK UP A FLAMING PAN - You may be burned.
c)
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d)
Use an extinguisher ONLY if:
I.
You know you have a Class ABC extinguisher, and you already know how to
operate it.
II.
The fire is small and contained in the area where it started.
III.
The fire department is being called.
IV.
You can fight the fire with your back to an exit.
www.airkinglimited.com
Power Unit
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED
CONTROL DEVICE.
WARNING:
TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
WARNING:
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
WARNING:
TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour Ain King SEV24S

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Power Unit Models: SEV24S, SEV28S, SEV30S, SEV24AB, SEV28AB, SEV30AB READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
  • Page 2: Installation Instructions

    SECTION 4 INSTALLATION INSTRUCTIONS Installing the Insert CAUTION: MAKE SURE POWER IS SWITCHED OFF AT Insert the power unit into the hole and secure to liner using the screws provided with the SERVICE PANEL BEFORE STARTING INSTALLATION. Liner (Figure 3). SECTION 1 Preparing the Insert Unpack hood from the carton and confirm that all pieces are present.
  • Page 3 Supply from home Hot (Black) Neutral (White) Figure 8 Ground (Green or Bare) If the grease filters become damaged, replace with the Air King Model SVGF-03 Grease Filters. Figure 5 From Hood Changing the Lamp To remove/replace the light bulb, remove the Attach the wire compartment to the power unit with two of the provided #6 blunt tipped filters using the procedure listed above.
  • Page 4: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Hood does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Wiring is not connected properly. Turn off power to unit. Check that all wires are connected. 2.
  • Page 5: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Collar Assembly 5S5299100 Blower Plate 5S1137002 Wire Compartment 5S1137003 Main Harness 5S1137049 Blower Assembly 5S2137810 Blower Assembly (AB models) 5S1140018 Fan Switch 5S1144085 Light Switch 5S4199018 Switch Plate 5S1142010 Knob 5S1142011 Lamp Holder 5S1137702 Bulb 5S1137014...
  • Page 6 NOTES www.airkinglimited.com 6728012 Rev. O 4-17 6 of 12...
  • Page 7: Unité De Puissance

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Unité de puissance Modèles: SEV24S, SEV28S, SEV30S, SEV24AB, SEV28AB, SEV30AB LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Installation de l’encastrement AVERTISSEMENT : ASSUREZ-VOUS QUE Insérez l'unité de puissance dans le trou et fixez-la au revêtement utilisant les vis L’ALIMENTATIONE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE fournies avec le revêtement (Figure 3). COMMENCER L’INSTALLATION.
  • Page 9: Alimentation De La Résidence

    Alimentation de la résidence Vivant (noir) Neutre (blanc) Figure 8 Terre (vert ou nu) Si les filtres anti-graisse deviennent endommagés, les remplacer avec les filtres anti- graisse modèle SVGF-03 de Air King. De la hotte Remplacement des lampes Fixez le compartiment de câblage à l’unité de puissance avec deux des vis #6 à tête Pour enlever/remplacez l'ampoule, enlevez les filtres en suivant le processus indiqué...
  • Page 10: Guide De Dépannage

    Guide de dépannage Trouble Cause possible Solution suggérée 1. La hotte ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur peut être déclenché. 1a. Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à EN (ON). 1b.
  • Page 11 TABLEAU DES PIÈCES DE RECHANGE # de pièce de Qté. Description remplacement Assemblement de collier 5S5299100 Plaque de ventilateur 5S1137002 Compartiment à câblage 5S1137003 Harnais principal 5S1137049 Assemblement de ventilateur 5S2137810 Assemblement de ventilateur (modèles AB) 5S1140018 Interrupteur du moteur 5S1144085 Interrupteur du lampe 5S4199018...
  • Page 12 REMARQUE www.airkinglimited.com 6728012 Rev. O 4-17 12 of 12...