Section 3. User Operation Of The Variable-Speed Controller; The Controller Interface; Basic Functions; Off Mode - Jandy Pro Series JEP-R Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the
ePump™ electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard resulting in severe personal injury or death.
2. Install the normally-closed fireman's switch
to the timeclock assembly. (See timeclock
manufacturer's instructions for details.)
3. Connect the main timeclock contacts to the
booster pump power input per the booster pump
installation manual.
4. Connect one side of the fireman's switch to
the Controller at J3 REMOTE CONTROL,
COMMON.
5. Connect the other side of the fireman's switch to the
controller at J3 REMOTE CONTROL, INPUT 4.
6. Set the timeclock to the desired on/off times.
7. Turn on all switches and the main breaker feeding
power to the variable-speed pump.
8. If the installation is working properly, the
fireman's switch will open 20 minutes before
the booster pump shuts down, the variable-speed
pump will continue to run for 30 minutes, and the
Controller will display
, where
FOR XX:XX
until variable-speed pump shutdown.
Section 3. User Operation of
the Variable-Speed
Controller
The variable-speed controller contains an advanced
microcontroller that provides a simple yet sophisticated
interface to operate your variable-speed pump for
maximum efficiency and enjoyment of your pool.
The controller allows operation of the variable-speed
pump in three ways: Manually, from built-in timers, and
remotely via contact closures.
3.1

The Controller Interface

The controller interface panel provides both timed and
manual speed controls for the variable-speed pump.
Four (4) speeds are directly available on the panel, while
four additional speed presets may be accessed via the
key.
MENU
The up and down keys are used to adjust the pump
speed. Speed is saved as it is adjusted. No further
action is required to save the new speed setting after
adjustment.
As shown below, preset speed "
eStar feature. Hence, it is intended to be assigned an
energy-efficient filtration speed, as determined by the
installer.
JEP-R Variable-Speed Pump Controller
PUMP WILL REMAIN ON
is the time remaining
XX:XX
" is assigned to the
|
Installation Manual
3.2

Basic Functions

The controller has two (2) operational modes: User
Mode and Setup Mode.
User Mode
In the User Mode, the controller provides access to
pump control options including:
• Manual start and stop of pump
• Pump speed setting
• Timeclock setup and operation
Setup Mode
The Setup Mode allows the user to configure the
controller. Setup options include:
• Time-of-day setting
• Labeling of pump speeds
• Display light control
• Language selection
• Run duration
3.3

OFF Mode

When the pump is off, the controller displays
PRESS SPEED OR MENU/00:00 PUMP IS OFF
00:00 is the time-of-day clock.
PRESS SPEED OR MENU
12:00AM
2
3.4

RUN Mode

When the pump is running, the controller displays
N:LABEL/00:00 RPM:XXXX
number and label of the selected speed, 00:00 is the
time-of-day clock, and xxxx is the pump speed.
10:00AM
2
ENGLISH
PAGE 11
PUMP IS OFF
3
4
MENU
, where n:label is the
2:SPEED 2
RPM: 1200
4
3
MENU
, where

Publicité

Table des Matières
loading

Table des Matières