INSTALLATION INSTRUCTIONS
ECO-TOUCH
PROGRAMMABLE TOUCH SCREEN WALL CONTROL
®
*Compatible with SHR/VHR (HRV), SER (ERV) and FLEX
CAUTION
Failure to comply with the following can cause erratic operation of the unit:
Disconnect the power to the HRV/ERV unit before installing the ventilation control. Ensure that power is reconnected once ventilation control has been
installed. Failure to disconnect power before installation could damage the Controller.
•
Never install more than one central ventilation control per unit.
•
Keep control low voltage wiring at least 1 foot (305mm) away from motors, lighting ballasts and light dimming circuits. Do not route control wiring alongside
house power wiring.
•
Ensure the wires are securely connected to the unit and wall control.
BEST PRACTICES
For optimal operation of the ventilation control, the following best practices are recommended during installation:
•
The location of the ventilation control could affect the optimum performance. Therefore, it is recommended that the wall control be installed in a central location,
away from direct sunlight and other sources of direct heat or cold such as an outside wall or adjacent to windows.
•
Do not install ventilation controller on wall where cavity is opened to other areas. Example: Furnace return in wall cavity. If so, seal the back plate center opening with tape.
INSTALLATION STEPS
1
1
1
1
3
3
3
3
Troubleshooting
If error code 01 is displayed on the touchscreen control, disconnect the power to the HRV/ERV for 10 seconds and re-connect the HRV/ERV to power.
Series units
®
1
Detach front module from back plate
by pressing the tab (located at the
bottom of the control casing).
NOTE: Be sure not to exert too
much pressure on the tab.
3
Insert signal wires (2) into the
terminal block, located on the
backside of the front module.
Secure them in place by tightening
the terminal screws using a small
3.0 mm slot/flat head screwdriver
(not included).
NOTE: The terminals are not po-
larity sensitive.
5
Leave operating instructions with home owner.
5
5
5
5
2
2
2
Guide the signal wires (2) through the
central opening of the back plate and
2
2
mount this plate to either a standard
electrical device box or directly to the
wall using screws. If required, use
wall anchors.
NOTE: Be sure the screws are secure
but do not over tighten. This may re-
sult in damage to the back plate.
4
Attach front module to mounted
4
4
back plate, first by hooking the top
of the front module to the top clips
4
4
of the back plate, then by pressing
the bottom of the front module until
you hear a 'click'.
Ensure the ventilation system oper-
ates correctly.
NOTE: Be careful not to pinch or trap
signal wires when attaching the front
module to the back plate.
Item #: 400608
Rev Date: 2016-06-06