150-Watt Transformer
Installation Instructions
PackaGe iNcluDes:
• 150-Watt Transformer
• Instructions for Use
LISTED
E181950
5G45
Features
The Aquascape PRO LVL lighting system operates on low
voltage and is safe for use in water features. It is good practice
whenever working in or near water to have all electrical devices
Instructions
1) Split one end of LVL cable and strip wire insulation,
exposing at least half an inch of wire on each side.
2) Slide bare wires of LVL cable under pressure plates
on bottom of transformer.
3) Tighten down pressure plates with terminal screws
provided. Make sure wire insulation clears
pressure plates.
4) Mount water-tight transformer within 1 foot
(30 cm) of a standard grounded electrical outlet
(120 volt only) with a weatherproof covered GFCI.
(test regularly)
5) It is best to mount transformer above ground
level, out of heavy traffic areas (ie. on a piece of
pressure-treated wood, on side of house, etc..). Use
landscape materials such as plantings, driftwood
or boulders to help camoflage transformer.
6) Lay the flat LVL cable along the outside edge of the
pond. (see light instructions to attach click and
plug connectors to LVL cable)
Setting Timer
Transformer's photocell turns unit on at dusk.
Off
A
On - turns unit on
B
Auto - turns unit on at dusk / off at dawn
C
4 H - turns unit on at dusk/off after 4 hours
D
6 H - turns unit on at dusk/off after 6 hours
E
8 H - turns unit on at dusk/off after 8 hours
F
item #01002.042008
plugged into a ground fault circuit interrupter (GFCI) that
has been installed by a licensed electrician.
1
3
5
D
E
4H
6H
F
C
8H
AUTO
B
ON
OFF
A
©2008 Aquascape, Inc. • All Worldwide Rights Reserved
WarNiNG
For use with Aquascape PRO Underwater Lights. This transformer should not be used with
either swimming pools or spas.
• Do not use extension cords.
• Do not submerge transformer.
• Do not connect two or more
• Do not use with a dimmer.
power supplies in parallel.
• Do not install additional cable lengths to
submersible fixtures.
Disclaimer
Except as stated below, there are no other representatives or warranties related to the product or its
use. THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR THE USER'S INTENDED
USE, AND THE USER ASSUMES ALL RISKS AND LIABILITIES WHATSOEVER IN CONNECTION THEREWITH.
Seller and manufacturer's only obligation is the repair and or replacement of the Outdoor Low Volt-
age Transformer as stated below. ALL IMPLIED WARRANTIES ARE HEREBY EXCLUDED, INCLUDING,
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Neither seller nor the manufacturer shall be liable for any injury, loss, or damage whether
direct, incidental, or consequential arising out of the use or inability to use the product. The national
Electric Code, Article 680-41 (A), requires a Ground Fault Circuit Interrupter (GFCI) to be installed in
the branch circuit supplying fountain equipment rated above 15 volts.
2
4
Troubleshooting
• If lights cycle on and off, remove power.
• Is lamp burned out? Use another lamp
• Bulb life can be greatly increased by
• To maximize the life of the transformer
1
1
YEAR
YEAR
WARRANTY
WARRANTY
1
1
The Outdoor Low Voltage Transformer is war-
GARANTIE
GARANTIE
ranted against defective materials and work-
manship for a period of 12 months from the date
DE 1 AN
DE 1 AN
of purchase by the user. Contact the installer or
place of purchase if the Outdoor Low Voltage
Transformer should fail within the warranty pe-
riod. Warranty shall be totally null and void in
2
2
the event the Outdoor Low Voltage Transformer
YEAR
YEAR
is abused, misused, or used for a purpose other
than for which the product is intended.
WARRANTY
WARRANTY
2
2
GARANTIE
GARANTIE
DE 2 ANS
DE 2 ANS
Cycling is caused by overload or short
3
3
YEAR
YEAR
circuit. Correct fault and restore power.
to test.
WARRANTY
WARRANTY
setting timer on the transformer so the
3
3
light(s) only operate during the desired
GARANTIE
GARANTIE
viewing times.
DE 3 ANS
DE 3 ANS
and lights, the transformer should only
be operated at 80% of its total wattage
(ie. 80% of 60 watts = 48watts)
Made in China for
Aquascape, Inc.
St. Charles, IL 60174 • Brampton, ON L6T 5V7
www.aquascapeinc.com
IDD 08046255-080059

Publicité

loading

Sommaire des Matières pour Aquascape Pro 01002.042008

  • Page 1 WarNiNG For use with Aquascape PRO Underwater Lights. This transformer should not be used with 150-Watt Transformer either swimming pools or spas. • Do not use extension cords. • Do not submerge transformer. • Do not connect two or more •...
  • Page 2 N’utilisez ce transformateur que pour des lumières immersibles Aquascape PRO. Il ne doit Transformateur de pas être utilisé pour une piscine ou une spa. • N’utilisez pas de cordons de rallonge. • N’immergez pas le transformateur. • Ne raccordez pas deux ou plusieurs •...

Ce manuel est également adapté pour:

01002984869907098375