ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with a
"Warnings" leaflet and an "Instruction booklet". These should both be read
carefully as they provide important information about safety, installation, ope-
ration and maintenance. This product complies with the recognised technical
standards and safety regulations. We declare that this product is in conformity
with the following European Directives: 2004/108/EEC and 2006/95/EEC (and
subsequent amendments).
1) GENErAL SAFETY
WArNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The " Warnings" leaflet and "Instruction booklet" supplied with this product
should be read carefully as they provide important information about safety,
installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according to the
provisions set out by current standards. Keep nylon or polystyrene bags out
of children's reach.
• Keep the instructions together with the technical brochure for future reference.
• This product was exclusively designed and manufactured for the use specified
in the present documentation. Any other use not specified in this documen-
tation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting from
improper use of the product, or use which is different from that expected and
specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the following
European Directives: 2004/108/CEE, 2006/95/EEC, 98/37/EEC and subsequent
amendments. As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in order to achieve
a good safety level.
• The Company declines all responsibility for any consequences resulting from
failure to observe Good Technical Practice when constructing closing structures
(door, gates etc.), as well as from any deformation which might occur during
use.
• The installation must comply with the provisions set out by the following
European Directives: 2004/108/CEE, 2006/95/EEC, 98/37/EEC and subsequent
amendments.
• Disconnect the electrical power supply before carrying out any work on the
installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply, having
a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted just before the
power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for closure
(doors, gates etc.) and all system components provided with an earth termi-
nal.
• Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
• Position at least one luminous signal indication device (blinker) where it can
be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised by
the company.
• Instruct the product user about the control systems provided and the manual
opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation
area.
• Keep radio control or other control devices out of children's reach, in order to
avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the automation
system, and always request the assistance of qualified personnel.
• Anything which is not expressly provided for in the present instructions, is
not allow
2) GENErAL OUTLINE
Electromechanical piston designed to automatically operate residential gates. The
irreversible gearmotor keeps the gate locked both in the closing and opening
positions, making the use of the electric lock redundant.
The actuator is supplied with an electronic torque limiter. The unit is controlled
by means of an electronic control board with torque adjustment. End-of-stroke
operation is controlled by two magnetic limiting devices.
The actuator features an obstacle detection system in compliance with EN12453
and EN 12445 Standards.
INSTALLATION MANUAL
Installation must be carried out using the safety devices and controls prescribed
by the EN 12978 Standard.
The following optional accessories are available on request:
- Buffer battery kit mod. KIT-BATT-BT
Allows operation of the automation even when there is no mains power supply
for a short period of time.
3) TECHNICAL SPECIFICATIONS
3.1) GEKO-S
Power supply : ................................................................................................................ 24V d.c.
Motor revolutions : .................................................................................................3800 min
Absorbed power : ................................................................................................................40 W
Absorbed current : ..............................................................................................................1.5 A
Push and pull force : .......................................................................................................2000 N
Working stroke : ............................................................................................................ 280 mm
Stem speed : .................................................................................................. 14 mm/s approx.
Impact reaction : ................................... Torque limiter aboard LOG-GK control board
End-of-stroke limitino devices: ..............................Magnetic, built-in and adjustable
Manual manoeuvre : ..............................................................................................release key
No. of manoeuvres in 24hours: .................................................................60 manoeuvres
Max. leaf length : ........................................................................................................1800 mm
Max. leaf weight : .......................................................................................................... ~250 kg
Environmental conditions: ...............................................................from -15 °C to +60 °C
Protection level : .................................................................................................................. IP 44
Dimensions : ...................................................................................................................See fig.1
Controller weight : ............................................................................................................. ~5kg
Lubrication : ................................................................................................ permanent grease
3.2) BATTErY KIT KIT-BATT-BT
Charging voltage: .......................................................................................................27.2V d.c.
Charging current: ........................................................................................................... 130mA
Outside temperature when values were measured: ...............................................25°C
Battery capacity: ............................................................................................... 2x (12V 1.2Ah)
Flat battery protection threshold: ...........................................................................20.4Vdc
Battery charging time: .............................................................................................. 12/14 hrs
4) INSTALLATION OF THE ACTUATOr
4.1) Preliminary checks
Check that:
• The gate structure is sufficiently sturdy.
• Also make sure that the actuator pushes against the leaf reinforced section.
• The leaves move manually and without effort all along their stroke.
• The door stop plates are fitted at the end of both closing and opening
strokes.
• If the gate has not been recently installed, check the wear condition of all
components.
• Repair or replace faulty or worn parts.
The automation reliability and safety are directly influenced by the state
of the gate structure.
The diagram in fig. 2 should be used as a reference for installation and consult
the table for the distances in mounting the gate post.
The diagram in fig. 2 uses the following legend:
P
Gate post rear fastening bracket
F
Front leaf fastening fork
a-b "P" bracket installation value
C
Distance between fixing points (C = 993 mm)
D
Gate length
X
Distance from gate axis to the edge of the post
Z
Always over 45 mm (b - X)
kg
max. weight of leaf
leaf opening in degrees
α°
4.2)
How to read the installation distance tables
Select "a" and "b" according to the angle in degrees α° that the gate has to open.
The table shows the ideal value for "a" and "b" for an opening of α° = 90° at
constant speed.
If there is too large a difference between "a" and "b", the leaf will not travel smoothly
and the pushing or pulling force will fluctuate during its stroke.
To respect the opening speed and ensure the controller operates correctly, it is
best to keep the difference between "a" and "b" as low as possible.
When "a" and "b" are at their maximum, the piston develops the maximum
force.
The table has been worked out for a 40 mm thick medium-size gate. Al-
ways check that there is no possible collision between the gate and the
operator.
-1