5. Slide the air filter unit around the belt to your side.
Push-fit the hose onto it and relocate the hose
clamp to secure the hose to the unit. Turn on the
unit via the switch on the underside and close the
visor. Reposition the unit for comfort as desired.
6. Adjust the drawstring around your neck until it is
only possible to slip one finger inside the drawstring
(similar to the fit of a business shirt collar and tie).
Important: This adjustment is necessary for
maximum performance and respiratory protection.
Fig. 7.
7. Engage the earmuffs by pushing
them inward until they "click"
fully home. Fig. 8. Note: It may
be necessary to rock the helmet
sideways a little until they "click"
fully in. When hearing protection
is not required, "click" the
earmuffs outward. Fig. 9.
Important: Do not remove the earmuffs as the holes left in the shroud will
dramatically reduce the respiratory protection performance during use.
8. Switch on the air filter unit then lower the visor until it "clicks" fully closed - you may
need to press down on the top of the visor. Note: If necessary the visor pivot
tension can be adjusted by tightening or loosening the visor pivot bolts.
VISOR CLEANING, REMOVAL & REFITTING
Cleaning: If necessary the visor can be wiped clean using mild soapy warm water. Do
not use solvents or abrasive cleaners of any kind.
Although the visor is moulded from a high grade, scratch resistant polycarbonate, it
may eventually need replacing. Replacement visors can be ordered through your local
Triton outlet by quoting part no. PRA015.
REMOVE THE VISOR by unscrewing the two knurled
plastic pivot bolts.
REFITTING THE VISOR
1. Behind the visor pivot mount is a sprIng loaded
plastic nut. Insert a flat bladed screwdriver behind
the pivot mount and push to centralise the nut and
slightly compress the spring. Fig. 10. Sight through
the pivot hole to ensure the nut is properly centred.
2. With the spring compressed, fit the visor to the pivot
mount and screw the knurled plastic pivot bolt into
place, manoeuvring the nut as necessary. Fig. 11.
Repeat the procedure on the opposite side.
3. Adjust the pivot bolt until the visor pivots smoothly
yet will hold in the open position.