EN
Further safety instructions:
•
For installation and operation, the national regulations
and safety codes in force must also be adhered to.
•
Do not use the ENL 5 Vario Service-Unit in hazardous
areas.
•
Regarding the inlet screw joints, excessive tightening
forces must be avoided. This applies in particular to
conical screw joints.
•
The ENL 5 Vario Service-Unit will only function when
voltage is applied.
•
Do not use the test button for permanent drainage.
•
Use genuine spare parts only. This is imperative to
ensure perfect functioning.
Additional advice:
The removed control unit has no IP degree of
•
protection.
•
During installation, use spanner flat at the feed pipe
(wrench size SW27) as a back rest.
•
The service unit must not be dismantled.
min./max. operating pressure
(see type plate)
min./max. temperature
(see type plate)
Condensate inflow
Condensate outflow
Condensate
Housing
Weight (empty)
4
2. SAFETy INSTRuCTIONS
malfunction during operation!
Through incorrect installation and poor maintenance,
malfunction may occur at the ENL 5 Vario Service-Unit.
Condensate which is not discharged may cause damage
to plants and in production processes.
measures:
•
•
3. TEChNICAL dATA
0,8...16 bar (12...20 psi) or 1,2...16 bar (17...20 psi)
+1...+60 °C (+4...+140 °F) or +1...+70 °C (+4...+158 °F)
NPT ½ (½") internal
max. screw-in depth 1,5 mm (½")
G ¼ (¼") Ø 8 ... 10 mm hose connector
oil-contaminated + oil-free
aluminium + plastic, glass fibre-reinforced
0,5 kg (1.1 lbs)
ingersollrandproducts.com
CAUTION
Condensate drainage which is reliable in performance
directly optimizes the compressed-air quality.
To prevent damage and breakdowns, it is imperative
to observe the following:
a.
Exact compliance with the specifications of use
and with the performance parameters of the
ENL 5 Vario Service-Unit , in connection with the
case of application (see "Proper use" section)
b.
Exact compliance with the installation- and
operation instructions in this manual
c.
Regular maintenance and control of the ENL 5
Vario Service-Unit in accordance with the instructions
in this operating manual
80448699