Spinlock XX Série Mode D'emploi page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ZS-LCW/5 & ZS-LCW/10 Load Display
Zeroing
• From time to time it may be necessary to ZERO the reading due to
climatic conditions. To ZERO press the 'TARE' button on the software.
Overload
• If the software flashes OL the unit has experienced a significant
overload and will require re-calibration.
• OVERLOADING 200% OF SWL WILL RESULT IN PERMANENT
DAMAGE TO LOAD CELL
• A calibration certificate is available on the software CD and is valid for
12 months. The unit must be returned to Spinlock for re-calibration.
Battery Life
• The 2 x AA battery supplied with the unit will last between 2 and 6
hours on 'FAST' and upto 6 months on 'SLOW' mode depending on
the range of load measured.
• When the battery power is low the voltage display will turn red.
• VERY LOW VOLTAGE BATTERIES MAY GIVE INACCURATE READINGS.
• STORAGE WITH BATTERY CAN RESULT IN LEAKAGE AND DAMAGE.
Battery Replacement
• To change the battery carefully unscrew the 2 flat blade stainless steel
screws with an appropriate sized screw driver.
• Lift of the plastic battery cover and place down without disturbing
the seal.
• Lift out the batteries carefully.
• Replace with 2 x AA fresh batteries in as new condition.
• Replace the plastic battery cover and carefully locate the 2 bolts before
screwing evenly until the seal is compressed an even amount all round.
• DO NOT OVER TIGHTEN THE SCREWS
42
www.spinlock.co.uk
ZS-LCW/5 & ZS-LCW/10 Load Display
Safety
• Make sure any operator has read and understands the safe operation
before commencing any test.
• Always check before use that the cell is not dangerous or endangering
the boat or people aboard.
• Improper mounting and use can result in inaccurate results and
damage.
Technical Data
Sampling Rate
FAST mode - 20Hz
Range
Minimum 20m clear line of site
Max Error Band
(Linearity) 0.2% full range
Proof Load
150% of rated load
IP Rating
IP65 (Totally protected against dust. Protected against low
pressure jets of water from all directions -
limited ingress permitted)
Battery
2 x AA 1.5v
Battery Life
Minimum 2 hrs continuous
Temperature range
0 - 45 degrees Celsius
(Strong direct Sun light will damage the LCD)
Body Alloy
2014T6 Aeronautical specification
Plastic
Delrin type
Screen
250 micron Lexan
Adhesive (Screen)
3M® 467
Weight:
5 Tonne with Battery
10 Tonne with Battery
Dimensions
ZS-LCW/5
(nominal mm)
ZS-LCW/10
Software
For PC use only.
Rope Sense software is copyright of Spinlock ltd.
Neoprene protective cover fitting
(5 & 10 Tonne units only)
SLOW mode - 1Hz
0.385kg (0.85lbs)
0.700kg (1.55lbs)
152 x 57 x 40
175 x 75 x 40
43