Troubleshooting Guide; Care And Maintenance; Replacement Parts List; Need Help - ecolight UC1061-WH1-12LF0-E Mode D'emploi

Luminaire à installer sous une armoire
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7
Fig. 8
8
Fig. 9
Fig. 10
and the electrical supply ground wire should be connected using one of the wire
nuts. Connect the supply leads to the fixture wire leads using the supplied wire
nuts. The black leads from the fixture go to the black supply lead and the white
leads from the fixture go to the white supply lead (Fig. 9). Tighten the wire nuts
properly to prevent the wires from coming loose. If unsure of tightness, tape the
wire nuts to the wire using electrical tape. (Fig. 10). Carefully push any excess
wiring back inside the fixture.
9
8
Fig. 12
10
Fig. 13
11
Fig. 14

Troubleshooting Guide

Minor problems often can be fixed without the help of an electrician. Before doing any work
on the fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
Problem
Fixture doesn't light.
Fuse blows or circuit breaker
trips when light is turned on.

Care and Maintenance

IMPORTANT: This light fixture uses light emitting diodes (LEDs) to provide
light. LEDs do not have a filament to burn out like a traditional light bulb.
LEDs gradually emit less light over their lifetime, but will typically last 50,000
hours in a residential environment.
Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner
and soft cloth. When cleaning the fixture, make sure the power is turned off.
Do not spray cleaner directly onto any part of the fixture or LEDs.

Replacement Parts List

Keep this guide handy for
ordering replacement parts.

Need Help?

In the event you are missing a part or have questions regarding installation
please visit our website at www.goodearthlighting.com/support or
call the Customer Care Center 1-800-291-8838,
8:30 a.m.-5 p.m., CST, Monday-Friday.
Insert a flexible whip or NM cable (not included)
through the strain relief and tighten the clamp until it is
secure (Fig. 8). Allow enough wire length to make the
connection. WARNING: Make sure the POWER is OFF.
For safety and proper operation, the fixture must be
properly grounded. If unfamiliar with the methods of
properly grounding the fixture, consult a qualified
electrician. A copper ground wire is pre-attached to
the fixture. If the electrical box is made of plastic
and/or has a green or bare copper grounding wire
inside, the fixture grounding wire and the electrical
box ground wire should be connected using one of
the wire nuts. If the fixture is being connected using a
flexible whip or NM cable, the fixture grounding wire
Re-attach the wire compartment cover by hinging the
cover with the fixture chassis and closing (Fig. 11).
Press on the cover and secure the front lip under the
locking tab (Fig. 12).
Fig. 11
DD
Slide the fixture over until the narrow ends of the
keyhole slots are under the heads of the wood screws
(Fig. 13). Finish tightening the wood screws until they
are firmly seated and the fixture is tightly secured to
the mounting surface.
Re-install the diffuser (Fig. 14).
Cause
Power is off.
Bad connection.
Bad switch.
Discontinue use.
Hardware Kit
ZH-UC1061F00-WH1
- 3 -
Solution
Check if power supply is on.
Check cords and/or wiring.
Test or replace switch.
Call customer service.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Uc1061-wh1-18lf0-eUc1061-wh1-24lf0-eUc1061-wh1-30lf0-e

Table des Matières