1
VACUUM PACKAGING WITH REBER UNIVERSAL COVERS
5
(REBER universal covers are available in different sizes to be suitable for containers, jars, bowls, pots and pans of common domestic use)
-
Operate as described for vacuum packaging in container, making sure that the container edge perfectly adheres to the universal cover gasket.
-
In case of prolonged use on the same container, the cover gasket may show a groove caused by container edge. To avoid any problems, turn
the gasket upside down: the groove will disappear in a short time.
-
The gasket can be removed for washing purposes. After drying, place it correctly in its place; gasket can be washed only by hand, never in
dishwasher.
ELECTRONIC SETTINGS
Default set:
1-
Minimum electronic power of sealing of 2 units time/power, suitable for 95/105 microns bags furnished (potentiometer at lower green level);
starting work, with cold machine place the knob on second level and progressive lower the power.
2-
Pontentiometer (9) can multiply by 10 electronic set welding power. Use carefully.
Models 9709 NE - 9714 NEL - 9716 NEL – 9709 NELF – 9712 NEL are not equipped with potentiometer, only electronic setting via switches
3-
4-
is allowed.
The machine is set by automatic cycle vacuum/seal,
5-
It is possible to set to manual cycle by programming the electronic card.
6-
The machine is set by 10 secs. delay from reaching vacuum level before welding start (to reach more vacuum); this delay time can be set by
programming the electronic card.
7-
The machine is set by a waiting time at the end of welding to obtain a best quality seal; this waiting time can be stopped by press the start
switch (1) when the Led (12) is off, showing the end of welding operation.
THE POTENTIOMETER – only models N or NF (not present on NE, NELF and NEL models)
The potentiometer (9) sets the seal power of the appliance. GREEN sector = low, RED = high. For furnished bags use the potentiometer (Image 3) as
follows:
1-
First and second seal: place on ORANGE.
2-
Third and fourth seal: reduce of one sector on YELLOW. 3-
From fifth seal: reduce on GREEN.
4-
For extended and continuous use, the seal power can be reduced again QUITE TO zero to avoid pre-seal of the bags.
5-
The potentiometer can be used with high power (RED) for high thickness bags; this will reduce the possibility of continuous use of the
machine up to 1 cycle each 10 min.
INFO
Welding time could be different using different kind of bags even if thickness is the same; we suggest to test welding after changing welding time. Less
seal power = faster cycle.
IMPORTANT
If the machine is not used for a long period and/or in the case of non-adequate or low temperatures, it is recommendable, before using the machine, to try
it once without using the bag and keep the machine working in automatic cycle for one/two cycles.
WELDING POWER SETTING models 9709 NE - 9709 NEL - 9714 NEL - 9716 NEL – 9709 NELF –
97812 NEL To change welding power on appliances not equipped with potentiometer:
1-
Connect appliance to power supply.
2-
Push 10 times in 10 seconds the seal switch (2), green led will light on fast to indicate you are in setting mode.
3-
If green led do not light fast, re-start from point 1.
4-
Push the pump switch (1) once per each unit of time/power you need (default is 5 units), green led will light once per each time you push.
If pushing on pump switch (1) starts the pump, it means you didn't reach setting mode; re-start from point 1. 6-
5-
before starting normal operation with new seal power set; 7-
SETTING THE MACHINE TO MANUAL/AUTOMATIC USE
To set the machine to manual use, proceed as described below:
-
Unplug the machine from electric power or switch off main power switch (11) if present.
-
Press and keep pump switch (1).
-
Switch on the power switch (11) or connect the plug to power supply.
-
Wait for at least 5 seconds.
-
Release switch (1).
To set the machine to automatic use, proceed as described below:
-
Unplug the machine from electric power or switch off main power switch (11) if present.
-
Press and keep seal switch (2).
-
Switch on the power switch (11) or connect the plug to power supply.
-
Wait for at least 5 seconds.
-
Release switch (2).
(Settings will be permanent, until a new setting operation)
DEFAULT SETTING
To return to default setting:
-
Unplug the machine from electric power or switch off main power switch (11) if present.
-
Press and keep both pump and seal switches (1) and (2).
-
Switch on the power switch (11) or connect the plug to power supply.
-
Wait for at least 5 seconds.
-
Release switches (1) and (2).
New set will be permanent up to a new setting or reset to default.
Wait
10
seconds