Control Panel; Control Features - GE 30S BLM Serie Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

About the Control Panel
Displaying Temperature Setpoint
The control will display the temperature
setpoint anytime a button on the control
is pressed. After 30 seconds of inactivity,
the display will go blank. Note that the
Mode and Capacity selection (if equipped)
will remain illuminated in sleep mode. To
wake the control at any time to see the
temperature setpoint, press any button on
the control.
Turning on the Water Heater
There is no power button for this unit. Once
the water heater is wired and power is
supplied, it will be on. The display will show
the current water temperature setting.
To comply with safety regulations, the
controls are factory preset to 120°F (49°C).
To Adjust the Temperature
Follow these steps:
1. Press the + or - button on the control
panel key pad to desired temperature.
2. Press ENTER to accept the new setting.
Note: To change between °F and °C, press
and hold the Mode Select button.

Control Features

1. Display
2. Mode Select Button and Mode Indicator
Use this button to alternate between Normal and Vacation
modes. Enter key must be depressed to confirm selection.
3. Tank Capacity Selection Button and Indicator
Status (on some models)
Use this button to alternate between Normal, High and
X-High tank capacities. Enter key must be depressed to
confirm selection.
4. + Select Button
Use these buttons to increase the temperature setting or
vacation days.
5. - Select Button
Use these buttons to decrease the temperature setting or
vacation days.
6. Enter Key
Use this button to confirm temperature setting following
adjustment.
49-6000239 Rev. 0
8
1
9
2
3
7. Anode Reset and Replacement Indicator (if
equipped)
When the Anode text is illuminated and F70 fault is
displayed, the system has indicated that the anode rod
is approaching end of life and it is recommended to
replace it. Press button once to silence alarm. Press
and hold for 5 seconds to reset the anode alarm after
replacing. Call the Installer to replace the anode rod. The
Servicer contact info is located next to the rating plate of
the unit, or contact GE Appliances customer support at
GEAppliances.com/waterheater. Failure to replace the
anode rod will void warranty coverage and may result in
a tank leak. (See page 12 for instructions to change the
anode rod.)
8. Wifi Indicator Light
Lit when connected, flashing during configuration set up
mode.
9. Appliance Communication Module Port
For use with Service and optional accessory modules.
Visit GEAppliances.com/waterheaters for more
information.
4
6
5
7
7

Publicité

Table des Matières
loading

Table des Matières