HOSE KIT - Item. 35241
•
Purge the hose. To do this, close the gas cylinder valve and burn off the gas that is still in the
circuit by pressing the trigger.
•
When there is no more gas in the hose, disconnect the regulator from the cylinder.
•
Disconnect the quick connector from the heat-shrink gun.
•
Unscrew the nut that is in contact with the regulator using two open ended spanners
•
Replace the hose. (item. 35241)
•
Re-tighten the nut on the regulator using two open ended spanners; tighten firmly (to a torque of
16 N.m). Do not just hand-tighten only.
Re-connect the quick connector to the equipment. Carry out the start-up checks.
Remark: for an explanation of the hose manufacture date and for further details please refer to the
EXPRESS ISO 3821 Hose technical data sheet.
DEFLECTOR - Item. 35088
AIR CLIP - Ref. 35198
35280 g – GB-FR-NL-ES-PT-PL-Z0
35241
911
963/10
To prevent too much heat being transferred towards
•
the operator's hand.
Using the hex spanner supplied with the equipment fit
•
the deflector as indicated above.
Firmly tighten (16 N.m)
using two open ended spanners