Bedroom
Bedroom
Kitchen
Basement
On ceilings
Install smoke alarms as close as possible
to the centre of the ceiling. If this is not
possible, install the smoke alarm at least
30 to 50 cm from the wall or corner (due to
dead air space).
Rooms with gabled ceilings
Install the smoke alarm 90 cm from the
highest point (due to dead air space).
When installing a smoke alarm in a corridor
with a length of 7.5 metres or more. It is
recommended to install a smoke alarm in the
beginning and the end of the corridor.
Do not install a smoke alarm
- In a humid, dusty and smoky environment
- In rooms or areas where temperatures are below 4 °C or above 38 °C
- In the kitchen, bathroom or garage
- In drafty places
- Near a fan or air vent
- Above heating
Living room
Ceiling mounting
minimum 30/50 cm
Minimum 90 cm
5
ENGLISH
Attic
Corridor
Corridor
Corridor
Corridor