Power Requirements
Power
Voltage
Output
(V)
2 - kW
230
3 - kW
230
4.5 - kW
230
6 - kW
230
9 - kW
230
12 - kW
230
15 - kW
230
18 - kW
230
Flow Requirements
Your heater is factory set to accept input water flow entering on the left
and exiting on the right, this can be reversed by rotating the flow switch
180 degrees (ie:½ turn, see fig 6)
WARNING! The flow switch paddle can be damaged when reversing the flow
direction if it is lifted by more than 5mm from its housing and turned with
force. If the flow switch has been rotated it is important to ensure that it is
finally locked in the correct orientation perpendicular (at right angles) to the
flow of water.
3 Phase
Amp
Power
Output
9
6 - kW
13
9 - kW
20
12 - kW
27
15 - kW
40
18 - kW
53
24 - kW
66
79
To reverse flow: Loosen cap
and rotate Flow switch by
180 degrees as shown.
Always ensure the arrow
marked on the plastic flow
switch body is in the same
direction as the water flow
Factory set flow
www.elecro.co.uk
400 V Star /
Amp
230 V Delta
400 / 230V
9 / 15
400 / 230V
13 / 23
400 / 230V
18 / 31
400 / 230V
22 / 38
400 / 230V
26 / 46
400
35
Flow
Optional reverse
flow
Fig 6.
5