Electrical Requirements

Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes. The
following table provides the correct voltage, amperage and frequency that must be supplied to the
grill.
The supply must be from an individual grounded circuit that is protected by a circuit breaker and
rated per the specifications for the model as shown in the table below.
KENYON
Part #
B70050
B70056
B70060
B70062
B70080
B70082
B70085
B70090
B70051
B70057
B70061
B70067
B70081
B70086
If the electrical supply does not meet the product specifications, consult with a
licensed electrician before proceeding with installation!
Do not remove the GFCI device from the supplied power cord under any circumstances.

Countertop Installation

Your All Seasons
Grill is supplied with a factory installed polished stainless steel flange that
®
accepts four oval head wood screws for mounting. The trim flange of the grill is designed to hold
the unit firmly in place in the countertop. If desired, you may seal the edge of the countertop
beneath the trim flange. Use a soft bedding compound that will prevent damage if later
removal for service is necessary. We recommend a nonadhesive type of sealant, such as
plumber's putty, maximum compressed thickness of 1/16". Silicone may be used to seal the
glass edge only, if desired.
Allow a 2 inch (2") minimum clearance between the bottom of the grill and combustible
surface located below, ie: the upper edge of a drawer installed below the grill (Fig. 3, page
12). Failure to provide proper clearances and ventilation may result in a fire hazard.
Max Load
1300 Watts
1300 Watts
WARNING:
WARNING:
10
Power Supply
120V AC 11A 60Hz
240V AC 6A 60Hz
Plug Type
3 prong grounded
cord with GFCI
3 wire cord no plug