STUDER Innotec
Technical specifications
Parameters
Mains
Consumption standby on
mains side
Efficiency
Secondary fuse
Short circuit proof
Standby consumption on
battery side
Mains charging
Floating charging
After mains break
Protection class
Safety class
Operation temperature
Temperature protection
Information
In accordance with the following EN-norms:
EN60 335-1, EN60 335-2-29, EN 55 014, 55104, EN60 555-2, EN 60555-3.
Swedish SS433077 (Vibration).
Warning
Batteries can generate explosive gases – avoid open flames or sparks. It is not allowed
modifying the mains cable!
517/MBC User manual (En–Fr–De–Sp)
1-phase 230 V (100-260 V) 40-60 Hz. At 110 V mains voltage the
charging current is approximately 40 % of the nominal power.
30 mA (50 mA for the MBC 24-32/1)
>85 % (>90 % for the MBC 24-32/1)
"Car fuse" protection against reverse polarity on connected battery.
Without blowing the secondary fuse
<2 mA (<0.1 mA for the MBC 24-32/1)
Yellow LED lit (14.4/28.8 V). Maximum 20 hours charging time. Switch
to maintenance charging when current is ~5 % of rated current.
Yellow and green LED lit. Battery is fully charged (13.8/27.6 V)
Charger starts at 14.4/28.8 V, without battery or load the charger starts
at 13.8/27.6 V
IP65 (waterproof)
Class 1 for the MBC 12-15/1; MBC 24-08/1; MBC 24-32/1
Class 2 (no earth in the mains cable) for the MBC 12-06/1; MBC 24-
03/1
-25 °C to +50 °C
Switches off at 60 °C and starts again at 50 °C
2 / 8
MBC – User Manual
V1.0.0