Publicité

Liens rapides

1) Warnings
 DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
 DO NOT OPEN WHEN ENERGISED
 POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
 HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
 DO NOT PAINT
 TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, THE FIRST
CONDUIT RUN MUST HAVE A SEALING
FITTING CONNECTED WITHIN 18 INCHES
OF ENCLOSE. SUBSEQUENT CONDUIT
RUNS MUST HAVE A SEALING FITTING
CONNECTED AS CLOSE AS PRACTICAL TO
THE WALL OF THE ENCLOSURE, BUT IN
NO CASE MORE THAN THE SIZE OF THE
CONDUIT OR 50MM, WHICHEVER IS THE
LESSER.
 TO PREVENT IGNITION OF GROUP A, B, C
AND D ATMOSPHERES - SEE
INSTRUCTION FOR CHEMICAL
COMPATIBILITY
Avertissements :
 NE PAS OUVRIR DANS UNE ATMOSPHÈRE
EXPLOSIVE
 NE PAS OUVRIR SI L'APPAREIL EST SOUS
TENSION
 RISQUE POTENTIEL DE DÉCHARGES
ÉLECTROSTATIQUES - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
 RISQUE DE DÉCHARGES À HAUTE
TENSION. APRÈS AVOIR COUPÉ
L'ALIMENTATION, ATTENDRE 5 MINUTES
AVANT D'OUVRIR LE BOÎTIER
 NE PAS PEINDRE
 POUR RÉDUIRE LE RISQUE
D'INFLAMMATION DES ATMOSPHÈRES
DANGEREUSES, LE PREMIER PASSAGE
DE CONDUITS DOIT DISPOSER D'UN
COUPE-FEU ANTIDÉFLAGRANT
RACCORDÉ À 45,7 CM (18 POUCES) DU
BOÎTIER. POUR LES PASSAGES DE
CONDUITS SUIVANTS, UN COUPE-FEU
ANTIDÉFLAGRANT DOIT ÊTRE RACCORDÉ
AUSSI PRÈS QUE POSSIBLE DE LA PAROI
DU BOÎTIER, MAIS JAMAIS À UNE
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH
o
Document n
D191-00-201-IS-FRE
Feux flash xénon D1xB2X05, D1xB2X10, D1xB2X15 &
D1xB2X21 pour utilisation dans les zones dangereuses
Version 2
18-01-2021
MODE D'EMPLOI
DISTANCE SUPÉRIEURE À LA TAILLE DU
CONDUIT OU À 50 MM, LA DIMENSION LA
PLUS PETITE ÉTANT RETENUE.
 POUR ÉVITER L'INFLAMMATION DES
ATMOSPHÈRES DES GROUPES A, B, C ET
D, CONSULTER LES INSTRUCTIONS
RELATIVES À LA COMPATIBILITÉ
CHIMIQUE.
2) Spécifications et marquage
2.1 Classification des alarmes incendie
Les modèles suivants sont certifiés en tant que dispositifs à
signal visuel pour systèmes d'alarme incendie - dispositifs à
signal visuel en mode privé conformément aux normes
UL1638 / CAN/ULC-S526 lorsqu'ils sont utilisés avec des
calottes transparentes ou rouges :
D1xB2X05DC024 / D1xB2X10DC024 / D1xB2X15DC024 /
D1xB2X21DC024
Sortie lumineuse axée selon la norme UL1638 :
Modèle
D1xB2X05DC024 - 1Hz
D1xB2X05DC024 -
1,33Hz
D1xB2X05DC024 - 1,5Hz
D1xB2X10DC024 - 1Hz
D1xB2X10DC024 -
1,33Hz
D1xB2X10DC024 - 1,5Hz
D1xB2X15DC024 - 1Hz
D1xB2X15DC024 -
1,33Hz
D1xB2X15DC024 - 1,5Hz
D1xB2X21DC024 - 1Hz
D1xB2X21DC024 -
1,33Hz
D1xB2X21DC024 - 1,5Hz
sales@e2s.com
www.e2s.com
Page 1 sur 9
Puissance lumineuse en
candelas
Calotte
Calotte
transparente
rouge
20,44
5,89
14,47
4,17
11,1
2,13
69,81
23,66
49,42
16,75
35,71
8,57
98,61
31,83
69,81
22,53
50,44
11,53
215,85
70,74
155,12
50,84
137,47
45,05
Tél. : +44 (0)208 743 8880
Fax : +44 (0)208 740 4200

Publicité

Table des Matières
loading

Sommaire des Matières pour E2S D1xB2X05 Série

  • Page 1 AUSSI PRÈS QUE POSSIBLE DE LA PAROI DU BOÎTIER, MAIS JAMAIS À UNE _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200...
  • Page 2: Tension Plage De Nominale Tensions

    Classe I Div. 1 Groupe ABCD T4A Ta -55°C à +40°C Classe II Div. 1 Groupe EFG T4 Ta -55°C à +40°C _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200...
  • Page 3: Classification Par Classe/Zone Nec Pour Les États-Unis

    Les feux xénon D1xB2X21AC115 et D1xB2X21AC230 sont classés comme suit : classés comme suit : _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200 Document n...
  • Page 4: Marque Atex, Groupe Et Catégorie D'appareils

    Ex db IIC T4 Gb Ta -55°C à +50°C Ex tb IIIC T141°C Db Ta -55°C à +60°C _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200...
  • Page 5: Indices De Protection Ip

    En outre, l’appareil doit être nettoyé uniquement à l’aide d’un chiffon humide. _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200...
  • Page 6: Exigences Pour Une Installation Sécurisée

    Fig. 2 Accès au boîtier. Retirer les 2 vis M5 de chaque anneau d’accrochage _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200 Document n...
  • Page 7: Schémas De Câblage

    Consulter la section 5 de ce manuel pour l’accès au boîtier. 9) Câblage _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200...
  • Page 8: Mise À La Terre

    Fig. 7b Positionnement de la résistance de fin de ligne _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, Londres W3 7QH sales@e2s.com Tél. : +44 (0)208 743 8880 www.e2s.com Fax : +44 (0)208 740 4200...
  • Page 9: Réglage De La Fréquence De Flashs

    Éviter de regarder directement la être prises pour manipuler l’appareil. source lumineuse pendant des périodes La calotte optique du feu est interchangeable. Contacter E2S Ltd pour Le feu D1xB2X peut avoir des modes de flash différents, obtenir une calotte de remplacement disponible dans différentes comme indiqué...

Table des Matières