ENGLISH
3.6

Pump Lid Removal

1.
Make sure that the pump is turned OFF.
2.
Make sure that the switch to the circuit breaker to
the motor is turned OFF.
3.
Make sure all necessary isolation valves are closed
to prevent water from reaching the pump.
4.
Following the markings on the locking ring, turn
the ring counter-clockwise until the 'START'
markings align with the ports. See Figures 12.
5.
Carefully remove the lid with locking ring.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit before starting the procedure.
Failure to comply may cause a shock hazard resulting in
severe personal injury or death.
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or
injuries to persons, Zodiac
in accordance with the National Electrical Code
(NEC
), all local electrical and safety codes, and
®
the Occupational Safety and Health Act (OSHA).
Copies of the NEC may be ordered from the National
Protection Association, 1 Batterymarch Park, Quincy,
MA, 02169, or from your local government inspection
agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
Figure 12. Disengage Lock Ring
Jandy
Variable-Speed Pumps
®
WARNING
Pumps must be installed
®
®
Rotate locking ring
counter clockwise
Align START
with port
|
Installation & Operation Manual
Lid with
Locking
Ring
Figure 13. O-ring in Lid Assembly
Figure 14. Remove Pump Lid
Seal
Locking
Ring
Lid
Seal
Basket