Publicité

Liens rapides

INFINITY SERIES DESIGNER CLEAN FACE
30,000 BTU
Natural Gas & Propane
Installation and Operating Instructions
MODEL: INFINITY-50
(P4 certified at 52.7% for NG)
CLIENT # LC773211
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbour's phone. Follow gas supplier's
instructions
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or gas
supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
PLEASE READ THIS MANUAL BEFORE
INSTALLING OR USING THIS APPLIANCE.
SAVE THIS MANUAL FOR FUTURE
REFERENCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF
BURNS FROM THE HOT VIEWING GLASS IS
PROVIDED WITH THIS APPLIANCE AND SHALL BE
INSTALLED.
WARNING
any other appliance.
Page 1 of 55

Publicité

Table des Matières
loading

Sommaire des Matières pour Inca Metal Cutting INFINITY Serie

  • Page 1 INFINITY SERIES DESIGNER CLEAN FACE 30,000 BTU Natural Gas & Propane Installation and Operating Instructions MODEL: INFINITY-50 (P4 certified at 52.7% for NG) CLIENT # LC773211 WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
  • Page 2 SÉRIE INFINITY DESIGNER CLEAN FACE 30,000 BTU GAZ NATUREL ET PROPANE Manuel D’installation et Guide de l’utilisateur MODEL: INFINITY-50 (Certifié P4 à 52,7% pour NG) CLIENT # LC773211 AVERTISSEMENT ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU D'EXPLOSION OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
  • Page 3: Table Des Matières

    Table of Contents IMPORTANT SAFETY INFORMATION …………………………………………………………….. 4 – 6 INTRODUCTION ........................Specifications, Appliance Dimensions & Installation Codes ......... 7 - 8 Features, Remote Control Functions ..............9 - 11 Intended Use ......................12 General Safety ....................12 - 13 OPERATION ...........................
  • Page 4 WARNING THE GLASS IN THIS UNIT IS FRAGILE. DO NOT CHIP OR KNOCK CORNER EDGES WHEN REMOVING OR REPLACING AS THIS WILL CAUSE CRACKING WHICH IS NOT COVERED UNDER WARRANTY. THE EXTERNAL GLASS TEMPERATURE MAINTAINS THE LATEST REGULATORY STANDARD OF LESS THAN 172°F FOR GLASS WITHOUT A MESH BARRIER This fireplace is equipped with double glass.
  • Page 5 WARNING  Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Follow instructions for proper installation  Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 6 WARNING AVERTISSEMENT Do not use this appliance if any part has Ne pas utiliser cet appareil s’il a été plongé, been under water. Immediately call a meme partiellement, dans l’eau. Appeler un qualified service technician to inspect the technician qualifié pour inspecter l’appareil et appliance and to replace any part of the remplacer toute partie du système de control system and any gas control which...
  • Page 7: Introduction

    1.0 INTRODUCTION 1.1 SPECIFICATIONS TABLE 1 ITEM NATURAL GAS (NG) PROPANE (LP) MAXIMUM INPUT: Hi 30,000 Btu/hr (8.79 kW) 27,000 Btu/hr (7.91 kW) MINIMUM INPUT: Lo 20,000 Btu/hr (5.86 kW) 20,000 Btu/hr (5.86 kW) MANIFOLD PRESSURE: 3.5” w.c. (0.87 kPa) 10.0”...
  • Page 8: Codes D'installation

    APPLIANCE DIMENSIONS INSTALLATION CODES This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe. Installation must conform to local codes. In the absence of local codes, installation must conform to the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane Installation Code CSA B149.1.
  • Page 9: Features, Remote Control Functions

    1.2 FEATURES Ignition system: Electronic pilot ignition system with thermopile and thermocouple flame detection. Gas control: * Optional* Gas control valve type: Automatic millivolt powered combination gas control valve with variable flame control for convenience and on/off switch. Optional digital remote on/off wall switch and/or optional wall thermostat (note: thermostats are not allowed in the United States).
  • Page 10: Countdown Timer

    When the Program Mode is activated, the unit will automatically be operating in the Thermostat Mode. The unit will turn on or off based upon room and set temperature. To activate the Program mode, press and release the PROG/TIME button. To change the settings for the Program mode, press and hold the PROG/TIME button for 5 seconds.
  • Page 11 Fan Control The unit must be ON to operate the Fan. The Fan will turn on after 6 minutes of operation. Once the Fan comes on, it can be controlled using the FAN button. Press the FAN button, and the fan icon and speed will appear on the LCD screen. Press the UP or DOWN button to control the fan speed (1-6).
  • Page 12: Intended Use

    1.3 INTENDED USE / USAGE PROPOSÉ This appliance is intended to be used as a zero clearance fireplace. This unit is certified for installation in a bedroom or a bed sitting room or a bathroom where the maximum input is within 50 cubic feet per 1000 Btu/hr, (i.e. 900 cubic feet for E unit &...
  • Page 13: Important S'il Vous Plaît Lire Attentivement Ce Qui Suit

    IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. It is not unusual for gas fireplaces to give off some odors the first time they are burned. This is due to the oils and sealants in the manufacturing process.
  • Page 14: Operation

    2.0 OPERATION LIGHTING INSTRUCTIONS - for Intermittent Pilot FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. BEFORE LIGHTING smell all around the appliance area for gas.
  • Page 15: Pour Plus De Sécurité, Lire Avant D'allumer

    Pilote intermittent POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT: Quiconque ne respecte pas à la letter les instructions dans la présente notice risqué de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. Cet appareil est équipé d'un dispositif d'allumage qui allume automatiquement le pilote. Ne pas tenter d'allumer le pilote à la main. Avant d’allumer la veilleuse, reniflez tout autour de l’appareil pour déceleur une odeur de gaz.
  • Page 16: Installation

    3.0 INSTALLATION 3.1 INSTALLATION & SAFETY NOTES / NOTES D'INSTALLATION ET DE SECURITE Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety. Failure to follow these instructions will void your warranty and may present a fire hazard.
  • Page 17: Minimum Clearances / Dégagements

    3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS FRAMING DIMENSIONS : 51.25’’ W x 36.5’’ H x 18.5’’ D MINIMUM CLEARANCES TO COMBUSTIBLES A = 24” MAXIMUM ALLOWABLE HEIGHT FROM FLOOR TO BOTTOM OF FIREPLACE IF BUILDING UP OFF THE FLOOR ON A PLATFORM B = 1.25”...
  • Page 18 1” x 4” Mantle can increase stud on within 45° edge Minimum above this height Height from Base of unit for Recess Clearances are in accordance with local installation codes and the requirements of the gas supplier. If you choose the optional recessed wall the maximum recess opening allowable from the front of the fireplace is 4”...
  • Page 19: Gas Line Installation

    3.3.2 GAS LINE INSTALLATION / INSTALLATION DE LA LIGNE de GAZ Install supply line using any piping approved for your installation meeting CAN/CGA 6.10, AA 3, ANSI Z21.24 or  Z21.45. A qualified gas fitter should install the gas line in accordance with all local building codes. If codes permit, coiled copper tubing may be used for gas supply.
  • Page 20: Direct Vent Information

    3.3.3 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION The unit must be connected to listed 2-ply aluminium venting and vent cap / termination kit, 5” flex vent on the exhaust side and listed 8” flex vent on the air intake side or can be used with Security Venting, Dura-Vent 5”x 8”...
  • Page 21 USE OF COUPLERS – WITH FLEX PIPE In the event of a puncture of the vent pipe or if an extension is needed couplers may be used. High temperature sealant shall be applied to the ends of the coupler and the coupler shall then be inserted into the flex vent.
  • Page 22 Security Venting The minimum vent system for horizontal termination must consist of: Dura-Vent adapter Part # directly on top of unit W175-0170 24” (609.6mm) vertical length of vent 90 degree elbow 12" (305 mm) horizontal length of vent Wall thimble Security Venting Horizontal termination cap The maximum horizontal vent system consists of: Dura-Vent adapter Part #...
  • Page 23 2-Ply Aluminum Flex Vent The minimum vent system for horizontal termination must consist of: 24” (609.6 mm) vertical length (measured to center of vent pipe) with a 90 degree bend and a 12” (305 mm) horizontal length (measured from center of vent pipe) Wall thimble Horizontal termination cap TTK58 The maximum horizontal vent system consists of:...
  • Page 24 VERTICAL VENT TABLE NOTE: All vent dimensions are measured from the (All values are in feet) appliance surface where the vent connects to the point where exhaust gases exit the termination. REMARQUE: Toutes les dimensions sont mesurées à partir d'aération de la surface de l'appareil où l'évent se connecte au point où...
  • Page 25 40’ 34’ 20’ 24” MINIMUM 12” MINIMUM (Example: Where A---A = Vertical @ 3.5’ B---B = Horizontal @ 8.75’) Page 25 of 55...
  • Page 26 USE OF SEALANT Sealant is required on vent system joints (figure 7), except Metal-Fab Sure-Seal direct vent system joints. On longer vent runs, especially vertical runs, sealant will ensure that the combustion air enters from outdoors, and not through the vent joints. Use high temperature sealant, available from local suppliers, on the inner pipe joint, applying the sealant around the outside of the male part of the vent.
  • Page 27 Typical Dura- Vent, Security Chimney & Metal-Fab Venting Installation: Vent terminals shall not be recessed into a wall or siding. Fireplace Horizontal Wall Vent Terminations The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes.
  • Page 28: Cage De Sécurité

    13.50” 13.50” 10.50” 10.50” Ø 10.00” Ø 10.00” 10.50” 10.50” ” ” Ø 8.00” Ø 8.00” OUTER PIPE 8” OUTER PIPE 8” WALL THIMBLE 10" WALL THIMBLE 10" 10.5 x 10.5 MIN OPENING 10.5 x 10.5 MIN OPENING VIEW OF SAFETY CAGE Mark a 10.5”...
  • Page 29 TOUJOURS vérifier les codes locaux avant l'installation VENTILATION. ETC DÉGAGEMENTS, peut varier d'ÉTAT (PROVINCE). CONSULT DURAVENT PARTS LIST OR INCA METAL CUTTING PARTS LIST FOR PART NUMBERS. FOR SECURITY CHIMNEY, ICC AND METAL FAB CONTACT YOUR LOCAL SUPPLIER. CONSULTEZ LA LISTE DES PIÈCES DURAVENT OU LA LISTE DES PIÈCES DE DÉCOUPE MÉTALLIQUES INCA POUR LES NUMÉROS DE PIÈCES.
  • Page 30 Termination above Roof Consult local codes for minimum vent cap height above the roof (X), vent must be a minimum of 2’ from any wall. To prevent water seepage; install the flashing with upper portion under the roofing material and the lower portion over the roofing material.
  • Page 31 In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code A vent shall not terminate directly above a † sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings Permitted only if veranda, porch, deck or...
  • Page 32: Logs, Rocks & Glass Media Installation

    3.3.4 LOGS, ROCKS AND GLASS PEBBLE INSTALLATION Burn media positions are critical to the safe and clean operation of this appliance. Never add any other material into the firebox. Use only with burn media supplied with this unit. Les positions des médias de brûlure sont critiques au fonctionnement sûr et propre de cet appareil.
  • Page 33 Step 3 Install the ceramic rocks aesthetically across the front of the burner pan (these can be moved once all burn media is in place to any position you are pleased with. Step 4 Install the 1 log to the left back of the burner pan. Make sure it lays close to the back wall behind the burner pan holes Step 5 Install the 2...
  • Page 34 Step 7 Install the 4 log to the left front of the burner pan. Again make sure it does not cover any burner holes. Step 8 Install the 5 log from the center front of the fireplace, across the burner where a single row of holes are and up onto the right hand end of the 1 Step 9 Install the 6...
  • Page 35: Glass Panel & Door Installation And Removal

    3.3.5 OUTER GLASS PANEL/DOOR REMOVAL & INSTALLATION. INNER & BE VERY CAREFUL WHEN HANDLING THE GLASS. DO NOT DAMAGE OUTER GLASS PANEL/DOOR REMOVAL 1/. Do not attempt removal until fireplace and glass are cool to touch. Remove front air intake louver 2/.
  • Page 36 INNER GLASS PANEL INSTALLATION. Carefully angle the front glass up into the top of the fireplace then lower into bottom glass channel. Lightly tighten the 3 thumb screws at the bottom. Install 3 thumb screws lightly to hold the top of the glass. OUTER GLASS PANEL/DOOR INSTALLATION.
  • Page 37: Initial Firing

    3.3.6 INITIAL FIRING When lit for the first few times, the appliance may emit an odor resulting from evaporation of paint and lubricants used in the manufacturing process. Open a door or window (or both) for ventilation. Anyone with a respiratory condition may need to leave the room during the initial firings.
  • Page 38: Factory Setting

    PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT. CAUTION ATTENTION PIECES NECESSITANT REGLAGE PENDANT LA MARCHE PEUT ETRE CHAUDE Factory Setting Natural Gas – open 1/4” (6.35mm) Propane Gas – Fully Open Aeration adjustment is important for the correct functioning of the appliance. Carbon build up, flame lifting or any malfunction due to improper aeration adjustment during installation is not covered under the factory warranty.
  • Page 39: Fan Access

    3.3.10 FAN ACCESSIBILITY / FAN ACCESSIBILITÉ TURN THE MAIN GAS & POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE, VOTRE FOURNISSEUR DE THE 3 FANS IN THIS FIREPLACE (TWO IN THE FRONT AND ONE IN THE MIDDLE AT THE BACK) ARE CONNECTED TO A HI/LOW THERMODISC, THE UNIT CAN NOT BE OPERATED WITHOUT THE FANS...
  • Page 40: Gas Valve Access

    The pictures above show the electrical box that controls the fan, the power cord attached and the strain relief connected to the box. / Les photos ci-dessus montrent la boîte électrique qui contrôle le ventilateur, le cordon d'alimentation fourni et le réducteur de tension connecté à la boîte. 3.3.11 GAS VALVE ACCESSIBILITY / ACCESSIBILITÉ...
  • Page 41: Maintenance

    4.0 MAINTENANCE 4.1 MAINTENANCE SAFETY / SÉCURITÉ ENTRETIEN WARNING AVERTISSEMENT TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE FIREPLACE TO COOL FOR UP TO 30 MINUTES BEFORE SERVICING. COUPER LE GAZ AU BRÛLEUR PRINCIPAL ET PERMETTRE AU FOYER DE REFROIDIR JUSQU'À...
  • Page 42: Glass Cleaning

    4.3 GLASS CLEANING / NETTOYAGE DE LA VITRE The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air. For best results, use a ceramic glass cleaner or polish (e.g. cerama bryte ®...
  • Page 43: Trouble Shooting

    4. Disconnect the gas line to the appliance and disconnect the gas line from the valve to the main orifice. / Débrancher la conduite de gaz à l'appareil et débranchez la conduite de gaz de la vanne à l'orifice principal. 5.
  • Page 44 3.Thermocouple installed 3. Make sure all wire connections at the gas properly valve terminals are tight and the thermocouple is fully inserted into the mounting bracket 4. Open wire connection in pilot 4. Check wire continuity and connections in circuit the pilot circuit 5.
  • Page 45: Replacement Parts

    6.0 REPLACEMENT PARTS When requesting service or replacement parts for your unit, please provide model name and serial number. All parts listed below may be ordered from an authorized dealer. Description Part# Certification Door Inner Front Glass 1905 ASTM C1048 Door Outer Front Glass 1904 ASTM C1048...
  • Page 46: Warranty

    INCA METAL CUTTING’S GAS FIREPLACE’S WARRANTY Your Inca Metal Cutting gas fireplace is guaranteed to be free of defects in materials and workmanship for a period of 5 years from the date of purchase. This covers: combustion chambers, heat exchangers and burners as well as stainless steel parts against tarnishing.
  • Page 47: Garantie De Protection

    Inca Metal Cutting neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Inca Metal Cutting will not be responsible for: over firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents, excessive venting configurations, insufficient make up air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 48: Conditions Et Limites (Suite)

    à des dommages indirects, accessoires ou indirects. Cette garantie définit les obligations et la responsabilité de l'Inca Metal Cutting à l'égard de l'Inca Metal Cutting foyer au gaz et toute autre garantie expresse ou implicite à l'égard de ce produit, ses composants ou accessoires est exclue.
  • Page 49: Label Information

    8.0 LABEL INFORMATION Page 49 of 55...
  • Page 50: Appendix A (Intermittent Pilot & Valve Kit)

    8.0 LABEL INFORMATION (continued) WARNING Electrical Grounding Instructions This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.
  • Page 51 APPENDIX A (AMERICAN FLAME VALVE INFORMATION) “S” connection to module (brown wire) “I” connection to module (orange wire) Page 51 of 55...
  • Page 52 APPENDIX A (Continued) Page 52 of 55...
  • Page 53 APPENDIX A (Continued) Special Features on the AF-4000 System The AF-4000 Module can be powered two different ways. The first is a standard 110 volt AC to 6.0 volt DC adaptor. This adapter is connected to the AF-4000 Module by connecting the two 1/4” female terminals from the adapter to the two 1/4”...
  • Page 54: Appendix B (Ng-Lp Conversion Kits)

    APPENDIX A (Continued) AF-4000 Wiring Diagram Brown APPENDIX B (NG – LP CONVERSION KITS) This kit will convert the fireplace to Natural Gas / Propane (as applicable). / Ce kit vous permet de convertir la cheminée au gaz naturel / propane (le cas échéant). The Elite models are designed to burn either natural gas or propane.
  • Page 55 INF50CKNGLP ou INF50CKLPNG par le ageny de service qualifié ci-dessus nommé / technicien qui accepte la responsabilité que la conversion a été dûment remplie selon les instructions contenues dans ce manuel. Inca Metal Cutting Ltd Unit 100 – 11091 Bridgeport Road...

Ce manuel est également adapté pour:

Infinity-50Infinity designer clean face serie

Table des Matières