MAINTENANCE AND TROUBLESHOOTING

Maintenance operations must be performed exclusively with original replacement parts
authorized by PENTAIR or the product warranty will be voided.
E
N
G
L
I
S
H
Fault
Leaks to the drain
during service or
when in stand-by
Hardness leak at
outlet
No brine draw
Brine suction
during the
backwash
TROUBLESHOOTING
Warning: When performing maintenance operations, always
lubricate parts with silicone grease (P/N 8500). You MUST NOT use
electrical or pneumatic tools. Use hand tools exclusively. When
removing internal spacers, use tools that have non-sharp tips to
avoid damaging components.
When it is necessary to disassemble over a third of the spacers, it is
recommended to replace all the O-ring gaskets.
Cause
Leak from the
During the service, keep the valve in pressure and alternatively
drain of the
disconnect pipes from fitting 2 and 4. If water leaks out from the pipe
distributor
it means that the pilot connected to this pipe is damaged and must be
replaced. Otherwise, if water leaks out from the valve fitting it means
that the piston seal is damaged.
Leak to drain
Disconnect flexible pipe from fitting 1 and from distributor. Block the
from the valve
fitting were the pipe was inserted from the distributor side with a
cap. Give pressure to the system and check if the leak stops, if this is
not the case the O-ring 6 could be damaged. Use the same procedure
disconnecting fitting 3, to check if the leak comes from O-ring 5.
Possible leak
A) Check the integrity of by-pass valve 9.
between inlet
B) In models with a backwash valve, check the integrity of the seal
and outlet or on
on the valve plunger.
the AB/BC seal
Injector / Drain
Case 1 (air suction): Check the brine valve
Case 2 (Injector sends back water):
The drain does not work because it is obstructed or there is
overpressure downstream from the drain.
Injector is obstructed
When the two items above have already been verified, check that
the resins are not impacted under the bottom distributor system.
Excessive flow
The system is bad designed. Check if the valve is equipped with the
rate at the drain
right injector/DLFC combination..
Warning:
If not differently specified, all the following operations
must be carried out in absence of hydraulic pressure. For
this reason, disconnect the water delivery line to the valve.
Corrective Action
22