23
23B
23 FLUSHING
Turn on Valve Lever Handle (23A). Run water for one minute. Repeat in hot and cold
positions. Reassemble the Spray Head (23B) to the Pull-Out Hose (23C) by turning
Spray Head (23B) clockwise.
Caution: Do not over tighten Spray hHead and Pull-Out Hose.
24
24B
24C
24D
24 AERATOR CLEANING
Over time, the aerator in your faucet may become clogged with debris. To clean the
aerator, unscrew Aerator Housing (24A) from Spray Head (24B). Remove Aerator Seal
(24C) and Aerator Cartridge (24D) from Aerator Housing (24A). Clean Aerator Cartridge
(24D) and Aerator Housing (24A). Reassemble faucet by reversing steps.
25
25A
25 PULL-OUT HOSE REMOVAL
To remove the quick connect attachment: Push up on Quick Connector (25A). Holding
gray Plastic Collet (25B) in place, pull downward on Quick Connector (25A) until Tube
(25C) is free.
23C
23A
24A
25B
25C
25A
ENGLISH
26
26 CARTRIDGE REPLACEMENT
Turn off water supplies and relieve pressure before working on your faucet.
3
Using a
/
" Hex wrench, loosen Set Screw (26A) and remove Handle (26B). Remove
32
Dome Cap (26C) by unscrewing counterclockwise. Unscrew Retainer Ring (26D) and
carefully remove Cartridge (26)E) by pulling it straight up and out.
Reassemble faucet by reversing steps.
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price
Pfister Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
6
26A
26D
26C
26E
26B