Maintenance
•
Locate the fan motor, unplug the lines connected with the fan motor, loosen the screws of the holding
bracket and fan motor bracket, remove the damaged unit and replace with a new one.
•
Reverse the above steps to reassemble.
REPLACING THE HOT GAS VALVE, DRIER AND EVAPORATOR
•
Remove the top panel.
•
Remove the refrigerant. Locate the drier and hot gas valve, open weld, replace the drier and hot gas valve,
and weld. Replace the refrigerant.
•
Reverse the above steps to reassemble.
•
If needed, replace the evaporator.
•
Remove the refrigerant. Remove the front and top panels, locate the evaporator, open the Process/Suction,
open the two welds, replace with a new evaporator. Replace the refrigerant.
Reverse the above steps to reassemble.
Troubleshooting
Machine does not run.
Step
Check
A1
Is the switched turned to on?
A2
Is there power to the machine?
A3
Is the bin full?
A4
Is the bin control adjusted?
A5
Is the high pressure safety switch
tripped?
A6
Is the selector switch out?
Machine runs but does not produce ice.
Step
Check
B1
Is water running over the
evaporator?
B2
Is the compressor running?
B3
Is there power to the
compressor?
B4
Is the switch defective?
B5
Is there water leaking from the
trough?
B6
Is the refrigerant pressure high?
If yes, proceed to
Turn on
Rewire
A4
Adjust
A6
If yes, proceed to
The following
troubleshooting chart.
B5
Replace
Repair the leak
Clean the condenser or
check HGV
12
If no, proceed to
A2
A3
Take ice out
A5
Reset clean condenser
Replace
If no, proceed to
B2
B3
Check for bad connection or
starting components
B6
B7