Dansensor MAP Mix Provectus Guide Utilisateur page 43

Table des Matières

Publicité

42
Guide utilisateur
Location Register write
0x0020
0x0030
0x0040
0x0041
0x0042
0x0043
0x0050
0x0051
0x0066
PBI-300864-F 06/2015
Encoding
"Mixer table 1"
Not used in MMP
offset values
(write only)
"Mixer table 2"
Not used in MMP
offset values
(write only)
Vacuum buffer
4 byte float. Saved in non volatile memory.
set pressure
Actual set point for the pressure in the vacuum buffer.
(Write only)
Typical 3.0 or 5.0 bars.
Vacuum buffer
4 byte float. Saved in non volatile memory.
hysteresis
Typical 0.3 bar. When buffer pressure reach "Vacuum buffer
(Write only)
set pressure" - "Vacuum buffer hysteresis" the valve is turned on.
When the pressure reaches "Vacuum buffer set pressure" it is
turned off.
Vacuum buffer
Not used in MMP, setting is ignored.
min on time
(times 100ms)
(Write only)
Vacuum buffer
Not used in MMP, setting is ignored.
min off time
(times 100ms)
(Write only)
Set mixer type
1 byte unsigned. Saved in non volatile memory.
(Write only)
0 = Not used in MMP (Ignored)
1 = CO
2 = N
3 = CO
4 = N
NOTE! It is NOT allowed to send 2-gas modes to a 3-gas mixer
or vice versa
Set input range for
1 byte unsigned. Saved in non volatile memory
voltage input. 0-
0 = 0 to 10V
10/2-10V
1 = 2 to 10V (default)
NOTE! If V-in (voltage input) is not used, always select the range
2 to 10 V and short circuit the input.
Output valve
1 byte unsigned.
mode (write)
See also read 0xAD06
0 = Stop mixer
1 = Start mixer