OPERATING INSTRUCTIONS
DATA LOG BT / DATA LOG 2 BT is a digital time switch designed to control any electrical installation.
It offers the possibility of performing different types of operations: ON and OFF at a set time, short-term
operations or pulses (1 to 59 seconds), and repetitive cycles (1 to 59 seconds or 1 minute to 23 hours and 59
minutes). All of them can be applied to channels C1 and C2 with DATA LOG 2 BT.
Furthermore, it includes a series of additional functions such as: automatic DST changes, 4 holiday periods,
adjustable screen brightness and programming from Smartphone / Tablet.
Menus can be displayed in several languages and they show the schedule for the current day on screen.
With 1 (DATA LOG BT) or 2 (DATA LOG 2 BT) independent and voltage-free circuits switched, which allows
the programming of up to 40 operations between channel 1 and / or channel 2.
INSTALLATION
WARNING: Installation and mounting of electrical devices must be carried out by an authorised fitter.
BEFORE PROCEEDING TO THE INSTALLATION, REMOVE POWER SUPPLY.
The device is internally protected against interference by a security circuit. However, some particularly strong
electromagnetic fields may alter its functioning. Interference can be avoided if the following installation rules
are taken into account:
- The device must not be installed near inductive loads (engines, transformers, contactors, etc.)
- It is advisable to devise a separate line for supply (provided with a network filter if necessary).
- Inductive loads must be provided with interference suppressors (varistor, RC filter).
If the time switch is used in combination with other devices in an installation, it should be made sure that the
constituted unit does not generate extraneous disturbances.
RESTORE SUPPLY ONCE THE DEVICE IS FULLY INSTALLED.
MOUNTING
Electronic control device of independent mounting in fuse box, with 35 mm. symmetrical profile, according to
EN 60715 standard (DIN Rail).
CONNECTION
Connect power supply according to the diagram in FIG. 2.
Phase and Neutral positions must be respected, checking the connections made. A wrong connection may
destroy the device.
START-UP
THE DEVICE MUST BE POWERED to be able to execute the installation control. When this happens, the
display will light up and the MAIN screen will appear.
When the device is not powered the display remains off, storing all the date and time programming during the
power-reserve period (4 years) thanks to the incorporated lithium battery. If installed without battery, the
device has a security power-reserve of approx. 48 hours.
With the device unpowered, when pressing the MENU
programming. If after 5 seconds no key is pressed, the display will be turned off again.
These devices have four keys for their setting and programming.
The display shows the following information:
Schedule with the day's operations (except on holidays). A schedule for each channel with 24 divisions in
which each segment represents 1 hour ON.
The display has a text line that will show the following information alternatively:
Current date PERMANENT operation Active HOLIDAY period
Complete time.
Manual operation symbol
. It blinks when a manual switching is activated and if the switching is
PERMANENT the symbol is fixed.
State of C1 / C2 circuits: ON
, OFF
SETTINGS
DATA LOG BT / DATA LOG 2 BT are factory programmed with the current date and time, and configured as
follows:
Time Mode:
24 h
Standard to DST change:
Automatic (last Sunday of March)
DST to Standard change:
Automatic (last Sunday of October)
Holidays:
NO (all 4 periods disabled)
Programs:
None
MANUAL OPERATION
Activated or disabled, temporarily reversing the state of the circuits manually from the main screen, by
pressing the ▼ C1 or ▲ C2 keys.
The symbol
will appear blinking on screen over the handled channel until we press ▼ C1 or ▲ C2
again, returning to the previous state.
PROGRAMMING
Programming is based on menus and submenus through which we can move to program operations or adjust
the device. The main menu can be accessed from the standby screen by pressing ✓. With keys ▼ and ▲ we
will move through the different menus and by pressing ✓ we will access them. To go back to the previous
menu we press C.
The details to be programmed always appear blinking on screen.
The structure of the menus is the following:
PROGRAMS
✓
ENTER
▲
DELETE
✓
NO TO ALL
▲
YES TO ALL
TIME SWITCH
2. Schedules
4. Low-battery symbol
6. C1 manual operation (blinking) /
C1 permanent manual (fixed)
8. Scroll down / C1 manual operation
10. Cancel option / Go back
12. C2 relay status symbol
14. 12 H / 24 H
16. Days of the week
key, the display temporarily lights up to allow
✓
PXX
✓
EDIT
▲
DELETE
✓
TYPE
✓
CHANNEL