Charging Process; Important Safety Instructions For All Battery Packs - DeWalt DCR019 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
ENGLISH
• Disconnect the charger from the outlet
before attempting any cleaning. This will
reduce the risk of electric shock. Removing
the battery pack will not reduce this risk.
• NEVER attempt to connect 2 chargers together.
• The charger is designed to operate on
standard 230 V household electrical power.
Do not attempt to use it on any other
voltage. This does not apply to the vehicular
charger.
SAVE THESE INSTRUCTIONS
Chargers
The DCB105 charger accepts 10.8 V, 14.4 V and
18 V Li-Ion (DCB125, DCB140, DCB141, DCB142,
DCB143, DCB180, DCB181, DCB182 and
DCB183) battery packs.
This charger requires no adjustment and is designed
to be as easy as possible to operate.
Charging Procedure (fi g. 4)
1. Plug the charger into an appropriate 230 V
outlet before inserting the battery pack.
2. Insert the battery pack (i) into the charger,
making sure the pack is fully seated in the
charger. The red (charging) light will blink
continuously indicating that the charging
process has started.
3. The completion of charge will be indicated by
the red light remaining ON continuously. The
pack is fully charged and may be used at this
time or left in the charger.
NOTE: To ensure maximum performance and life of
Li-Ion batteries, charge the battery pack fully before
first use.

Charging Process

Refer to the table below for the state of charge of
the battery pack.
State of charge
charging
fully charged
hot/cold pack delay
x
problem pack or charger • • • • • • • • • • • •
problem powerline
This charger will not charge a faulty battery pack.
The charger will indicate faulty battery by refusing to
light or by displaying problem pack or charger blink
pattern.
24
NOTE: This could also mean a problem with a
charger.
If the charger indicates a problem, take the charger
and battery pack to be tested at an authorised
service centre.
Hot/Cold Pack Delay
When the charger detects a battery that is too hot
or too cold, it automatically starts a hot/cold pack
delay, suspending charging until the battery has
reached an appropriate temperature. The charger
then automatically switches to the pack charging
mode. This feature ensures maximum battery life.
XR Li-Ion tools are designed with an Electronic
Protection System that will protect the battery
against overloading, overheating or deep discharge.
The tool will automatically turn off if the Electronic
Protection System engages. If this occurs, place the
Li-Ion battery on the charger until it is fully charged.
A cold battery pack will charge at about half the rate
of a warm battery pack. The battery pack will charge
at that slower rate throughout the entire charging
cycle and will not return to maximum charge rate
even if the battery warms.
Important Safety Instructions for All
Battery Packs
When ordering replacement battery packs, be sure
to include the catalog number and voltage.
The battery pack is not fully charged out of the
carton. Before using the battery pack and charger,
read the safety instructions below and then follow
the charging procedures outlined.
• Do not charge or use the battery pack
• Never force the battery pack into charger.
––
–– ––
––
–––––––––––––––––
–– • –– • –– • –– •
• Charge the battery packs only in designated
•• •• •• •• •• ••
• DO NOT splash or immerse in water or other
READ ALL INSTRUCTIONS
in explosive atmospheres, such as in the
presence of flammable liquids, gases or
dust. Inserting or removing the battery pack
from the charger may ignite the dust or fumes.
Do not modify the battery pack in any way
to fit into a non-compatible charger as
battery pack may rupture causing serious
personal injury.
D
WALT chargers.
E
liquids.

Publicité

Table des Matières
loading

Table des Matières