Electrical (23 °C ± 5 °C) < 75% RH
DC Voltage
RANGE
400.0 mV
4.000V, 40.00V, 400.0V
600V
Resolution : 0.1 mV on 400 mV range
NMRR : >50dB @ 50/60Hz
CMRR : >20dB @ DC, 50/60Hz, Rs=1k
Input Impedance : 10M , 30pF nominal (1000M for 400.0mV range)
Max input : 600VDC/VAC rms
AC Voltage
RANGE
1)
400.0mV
4.000V, 40.00V, 400.0V
4.000V, 40.00V, 400.0V
600V
Resolution: 0.1 mV on 400 mV range
CMRR : >60db @ DC to 60Hz, Rs= 1k
Input impedance: 10M , 30pf nominal
Crest factor (ACDC-100 TRMS): < 1.6: at full scale; < 3.2: at half scale
Max input: 600VDC/VAC rms
1)
Selection by Range button manually, and is specified from AC 40mV (AC 60mV for ACDC-
100 TRMS) and up
Resistance
RANGE
400.0
4.000k , 40.00k , 400.0k
4.000M
40.00M
Resolution: 0.1
on 400
Open Circuit Voltage : 0.4VDC typical
Continuity Tester
Open Circuit Voltage:
Range:
Accuracy:
Audible threshold:
Diode Tester
Open Circuit Voltage
Test Current (Typical)
Frequency
50Hz to 500Hz
50Hz to 60Hz
60Hz to 500Hz
50Hz to 500Hz
range
0.4Vdc typical
400.0
± (1.5% + 6dgts)
between 10 and 120 .
< 1.6 Vdc
0.4mA
± (0.3% + 3dgts)
± (0.5% + 3dgts)
± (1.0% + 4dgts)
± (0.8% + 6dgts)
± (0.6% + 4dgts)
± (1.0% + 4dgts)
± (2.0% + 4dgts)
11
Accuracy
Accuracy
± (4.0% + 4dgts)
± (1.0% + 4dgts)
± (1.5% + 4dgts)
± (2.0% + 4dgts)
Accuracy