4 - VALVE OPERATION
Note: You must pass through all the programming steps and come back in service position to
save the modifications that have been done during the programming mode.
Monday
Tuesday
Wednesday = d3-
Thursday
Friday
Saturday
Sunday
*1 = Monday, 2 = Tuesday, 3 = Wednesday, 4 = Thursday, 5 = Friday, 6 = Saturday, 7 = Sunday.
4.4
VALVE OPERATION DURING A POWER FAILURE
During a power failure, all the data will be saved and restored once the line power is restored.
The data can be saved for many years with no loss. The electronics will be inoperative, the
display shut down and all regeneration will be delayed. The electronics will restore all the
information to the time where the power failure occurred. The valve does not record the amount
of water used during a power cut.
During the power supply restoration, the hour display will flash to indicate that a power failure
occurred.
23
Regeneration day override (maximum number of day
between two regenerations)
Ex.: regeneration every 7 days (in time clock mode,
imperative adjustment)
Regeneration time
Ex.: 2.00 o'clock A.M. (only visible in delayed volumetric and
time clock modes)
Hardness of inlet water °tH
Ex.: 35°tH (only visible in volumetric mode)
Reserve capacity
Ex.: 1200 litres of reserve (only visible if reserve function is
activated)
Current day of the week*
Ex: current day is Thursday (only visible in weekly
time clock mode)
Activate
= d1-
1
= d2-
1
1
= d4-
1
= d5-
1
= d6-
1
= d7-
1
Deactivate
0
0
0
0
0
0
0