3 - Clean the filter using a vacuum or by
rinsing under water.
These pictograms show the procedure for cleaning the filter on the Turbo/Speed Air filter itself.
coNNEcTioN
Connect the 3 core cables as follows:
Brown wire = Live
Grey or Blue wire = Neutral
Black wire = Control Wire (Pilot Wire)
This wire must never be connected to the earth and must be isolated.
The black wire on the blower (Turbo / Speed Air) of the hydronic towel rails should not be connected.
v8_MANUAL_TURBO_SPEED_AIR_04_2015_A4.indd 3
replacing timer batteries
Batteries must be replaced when the Turbo/Speed Air does not respond to com-
mands sent by the timer (low or discharged batteries). Replace the batteries with 2
new Lr3 alkaline batteries.

FiLTEr cLEANiNg

The Turbo/Speed Air is equipped with a dust filter which will stop the Turbo/Speed
Air when it is saturated (see «Thermal safety»).
Filter indicator 1 lights steady red after 200 hours of use. In this case the blower will
stop working and the filter must be cleaned. Blower indicator 2 will remain steady
green regardless of the commands from the timer or infrared transmitter.
important: Power to the device must remain on for the filter cleaning alarm to be
turned off. (pictogram Nº5):
1 - Filter cleaning alarm:
FILTER indicator steady red.
4 – Reposition the filter in the same way
as shown in Figure 2, by sliding to the
left or right.
2 - Remove the filter by sliding to the
left or right of the appliance.
5 – Press the Start / Stop button for 3
seconds. This will turn off the alarm.
The filter alarm will be triggered again
after 200 hours of use.
P16MI407 - A01 - 04/15 | 3