After 10 seconds without programming or pressing the first two transmitter buttons, the receiver
will exit programming mode, issuing two acoustic signals of 1 sec. If upon programming a
transmitter the receiver memory is full, it will issue 7 acoustic signals of 0.5 sec. and exit
programming.
Configuration of transmitter programming in the receiver
Standard programming (default option, the receiver always is configured in multichannel)
The relays are activated 1st relay by channel 1 and 2nd relay by
channel 2 (3rd relay by channel 1 and 4th relay by channel 2)
Special programming
Press the transmitter channel to activate the relay 1 on the receiver
Press the transmitter channel to activate the relay 2 on the receiver
Press the transmitter channel to activate the two relays at once *
* If working in ON/OFF activation mode, relay 1 will act as impulse (monostable) and relay 2 as
ON/OFF. Therefore, on the first press relay 1 will close and open the contact and relay 2 will only
close. On the second, relay 1 will close and open the contact and relay 2 will open.
N.B.: Each transmitter can be configured independently on the receiver.
Total reset
In programming mode, the programming button is held down and the "MR" reset jumper is
bridged for 3 secs. The receiver will issue 10 short acoustic warning signals followed by others at a
faster pace to indicate that the operation has been successful. The receiver is now in
programming mode.
After 10 seconds without programming or quickly pressing the programming button, the receiver
will exit programming mode, issuing two acoustic signals of 1 sec.
10
Led R1
Led R2
Flashing
Flashing
ON
OFF
OFF
ON
ON
ON
3200683