Means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
INSTALLATION IN A BATHROOM
Ensure that your installation has a multipole separation with an
aperture of at least 3 mm.
Installation of the HAWAÏ in a bathroom is permitted in area 2 in view
of its IP34 classification (OFF position) and class II on one condition :
The whole electrical circuit for the bathroom, in accordance with
standard NFC15-100 (CEI 364...) must be protected by an earth
leakage circuit breaker with a maximum sensitivity of 30 mA which
could disconnect.
MOUNTING
6- Screw the wall support (3 screws).
7- Unscrew the seal board.
8- Hang the appliance on its wall support. In the same time, insert the
power supply cord through the back hole.
9- Connect phasis and neutral wires to the connector.
The power wire must be at the back of the appliance and must be
out of reach when the hair dryer is screwed on the wall.
10- Put the seal board and screw it.
To remove the appliance from its wall support, push the clip from
the bottom of the unit
GENERAL OPERATION
The appliance automatically starts when you remove the flex. It
automatically stops when the flex is no longer pulled.
TIMER OPERATION
The timer is a security which automatically stops the hair dryer if it is
continuously running for 15 mn.
After a security stop the handle must be put back in order to reset the
appliance. Then it can normally be used.
8