10
Accessories and consumables
Accessories
Part
SC conditioner
Base for test gas can
Consumables
Part
Carbon dioxide filter adjustment
O-ring 80 FPM ‒ 8 x 2 Viton, green
Test gas 2.2% vol. CH4 in synthetic air, test
gas can 1l, pressure approx. 12 bar
Test gas ExTox IR,
Test gas can 1 l, pressure approx. 12 bar
Other accessories and consumables are available for the prod-
uct. Please contact the SEWERIN sales department for further
information.
11
Technical data
Device connection
Max. inlet pressure
Max. flow rate
Height
Weight
Temperature range
Test gas can connection
Order number
PP05-Z3000
ZP10-10000
Order number
ZG06-10000
2800-8021
ZT03-10001
ZT47-10000
plug-in connection 5 mm
13.5 bar
180 l/h
119 mm
approx. 600 g
-20 °C ‒ +60 °C
7/16" 28 UNEF female threads
English │ 19