CD3000S-1PH UP TO 110A
TECHNICAL SPECIFICATIONS
GENERAL
FEATURES
Stocking
from -40
temperature:
to +100 °C
Operating
from –30
Temperature:
to +40°C
for higher
temp. consult
derating graph
Load isolation
2500Veff
Cover and
PolymericV2
Socket material
Heatsink
Anodized
alluminium
Delay switch
0.5 period max
ON time :
Delay switch
0.5 period max
OFF time:
Fan voltage:
230Vac ±15%
INPUT
FEATURE
Logic input
4 - 30Vdc
SSR
(ON ≥ 4Vdc
OFF < 1Vdc)
Current drain
12mA
Logic input
5 - 30Vdc
SSR Low
(ON ≥ 5Vdc
current
OFF = 1Vdc)
Current drain
5mA
Analogic Input
4-20mA
Loop powered
(Is required
(Option)
6,5Vdc
minimum)
A.C.
110÷240Vac
Input(option)
±15% 20mA
S0 - CD3000 15-25A
S7 - CD3000 60-90A
120
110
117
Size
Voltage
Ripetitive
range
peak reverse
voltage
480V 600V
(A)
(V)
15A
24÷480
1200
NA
25A
24÷480
1200
NA
35A
24÷600
1200 1600
45A
24÷600
1200 1600
60A
24÷600
1200 1600
90A
24÷600
1200 1600
110A
24÷600
1200 1600
ORDER CODE
CD3000S 1PH/
/
Size S0 e S1 DIN rail mounting
or panel mounting with 4mm
screw.
Size S4 e S5 panel mounting
with 4mm screw.
Latching
Max
Leakage
current
peak
current
one
cycle
(10ms)
(mAeff)
(mAeff)
(A)
150
230
15
150
230
15
250
400
15
250
600
15
450
1000
15
450
2000
15
450
1540
15
/
/
S3 - CD3000 35-45A
S8 - CD3000 110A
138 120
116
2
I
T
Frequency
Power
value
range
loss
for
fusing
tp=10m
I=Inom
sec
(Hz)
(W)
610
47÷70
18
610
47÷70
30
780
47÷70
42
1800
47÷70
54
4750
47÷70
72
19100
47÷70
108
11300
47÷70
137
/
/
/
110
Isolatio
n
Voltage
Vac
2500
2500
2500
2500
2500
2500
2500