6.3 Stove internal parts
Key:
1 - Combustion chamber
2 - Support left and right
3 - Cast iron exchanger
4 - Vermiculite side walls
5 - Vermiculite upper baffle
6 - Vermiculite rear wall
6.4 Electrical components
7
TROUBLESHOOTING
7.1 Alarm management
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm the shutdown procedure is automatically activated. Cancel the signalling by pressing button P3
and wait until the stove reaches OFF status. Eliminate the cause and restart the stove according to the normal
procedure described in this manual.
Listed below are the alarms that can appear on the control panel, with the causes and cures:
Key:
1 - Electronic board N100
2 - Safety thermostat
3 - Room probe
4 - Safety vacuum switch
5 - Fume probe
6 -Gearmotor
7 - Fume extractor
8 - Rear tangential fan
9 - Control panel
39
ANNA