8.

MOVING AND STORAGE INSTRUCTIONS

Store inside, in a cool, dry place.
8.1
Do not store the clips on the handle, clipped together, on or around metal, or clipped to cables. The clips
8.2
on the jump starter are live and will produce arcing or sparking if they come in contact with each other.
To prevent accidental arcing, always keep the clips on the storage holders when not using it to jump start
a vehicle.
If the jump starter is moved around the shop or transported to another location, take care to avoid/
8.3
prevent damage to the cords, clips and jump starter. Failure to do so could result in personal injury or
property damage.
IMPORTANT: Do not use and/or store the jump starter in or on any area or surface where damage could
occur if the internal battery should unexpectedly leak acid.
IMPORTANT:
8.4
• CHARGE IMMEDIATELY AFTER PURCHASE
• KEEP FULLY CHARGED
Charge the jump starter's internal battery immediately after purchase, after every use and every 30 days.
All batteries are affected by temperature. The ideal storage temperature is at 70°F. The internal
battery will gradually self-discharge (lose power) over time, especially in warm environments. Leaving
the battery in a discharged state may result in permanent battery damage. To ensure satisfactory
performance and avoid permanent damage, charge the internal battery every month.
9.

TROUBLESHOOTING

Jump Starter
PROBLEM
The jump starter won't jump
start my car.
The jump starter won't power
my 12V device.
The battery in the jump starter
won't hold a charge.
POSSIBLE CAUSE
Clamps are not making a good
connection to the battery.
The jump starter's battery is not
charged.
The vehicle's battery is defective.
The 12V device is not turned on.
The jump starter's battery is not
charged.
The 12V device draws more than
15A or has a short circuit.
The battery is bad (will not accept a
charge).
• 10 •
SOLUTION
Check for poor connection to battery
and frame. Make sure connection
points are clean.
Check the battery charge status by
pressing the Display button on the
front of the unit. The display will show
the percentage of charge.
Have the battery checked.
Turn on the 12V device.
Check the battery charge status by
pressing the Display button on the
front of the unit. The display will show
the percentage of charge.
Disconnect the 12V device. The
internal breaker will automatically
reset after a minute or two. Try using
the 12V device again.
Replace the battery.