8. TROUBLESHOOTING

CAUTION!
Refer to the chapters on safety.
8.1 What to do if...
Problem
The pouch is not
sealed correctly.
Final vacuum is
poor.
The cover does
not open.
The cover is
cracked or
broken.
The
buttons flash.
The vacuum
cycle is stopped
within a few
seconds and
the
flashes.
Possible cause
The sealing time is not correct.
The cover gasket is dirty or
worn.
The pouch is not placed
correctly on the sealing bar.
The sealing bar is worn (the
Teflon coating is burnt).
The blade placed under the
Teflon of the sealing bar is
broken.
The set vacuum level is not
correct.
The cover gasket is dirty or
worn.
The cover is not closed
correctly.
No power supply.
Damaged cover.
"Reconditioning cycle"
and
in progress.
The cover gasket is dirty or
worn.
button
ENGLISH
Solution
Change the sealing time.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
Position the pouch correctly.
Replace the sealing bar (contact
the Technical Assistance
Service for a replacement).
Replace the blade (contact the
Technical Assistance Service for
a replacement).
Change the vacuum level.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
Close the cover correctly.
Make sure that objects or dirt
are not found between the cover
and tank.
Wait until the power supply is
restored.
Replace the cover (contact the
Technical Assistance Service for
a replacement).
Wait for the end of the
"reconditioning cycle" (15
minutes).
Clean or replace the gasket of
the cover and check that it is
closed properly.