Range of application • Campo de aplicación
english
Domaine d'utilisation • Área de utilização
The BEKOMAT 16 CV serves to dis-
charge condensate at places with a tem-
porary negative pressure (< 1 bar (abs)
/ 14 psi) and where backward suction
of the condensate must be prevented.
During negative pressure conditions,
condensate will not be discharged, this
possibly resulting in a backup. Subse-
quent to a rise in pressure to approx. >
1.8 bar (abs) (26 psi), condensate will be
discharged again and a possible backup
reduced due to a special function.
A centrifugal compressor which is able
to take up a no-load mode (vacuum) in
individual stages represents a typical field
of application.
Function • Funcionamiento
english
Functionnement • Funcionamento
The condensate flows through the feed
line (1) into the BEKOMAT 16 CV unit
and accumulates in the container (2). A
capacitive sensor (3) continuously regis-
ters the liquid level and passes a signal
to the electronic control as soon as the
container is filled.
The pilot valve (4) is activated immedi-
ately and the diaphragm (5) opens the
discharge pipe via the check valve (6) in
order to discharge the condensate.
In the case of negative pressure (< 1
bar (abs) / 14 psi) the check valve (6)
shuts and prevents the condensate from
flowing back.
The pressure difference at the check
valve is < 0.1 bar (1.45 psi).
When the BEKOMAT 16 CV is empty,
the discharge pipe will be closed tight, in
sufficient time before any unnecessary
losses in pressure may arise.
BEKOMAT 16 CO CV