ORDERING INFORMATION AND TROUBLE SHOOTING

5 ORDERING INFORMATION

Part Number
Description
77040000*
MasterBus terminating device*
77040020
MasterBus connection cable (UTP patch cable), 0,2m / 0.6ft
77040050
MasterBus connection cable (UTP patch cable), 0,5m / 1.6ft
77040100
MasterBus connection cable (UTP patch cable), 1,0m / 3.3ft
77040300
MasterBus connection cable (UTP patch cable), 3,0m / 10ft
77040600*
MasterBus connection cable (UTP patch cable), 6,0m / 20ft*
77041000
MasterBus connection cable (UTP patch cable), 10m / 33ft
77041500
MasterBus connection cable (UTP patch cable), 15m / 49ft
77042500
MasterBus connection cable (UTP patch cable), 25m / 82ft
77050000
Set to assemble UTP patch cables: 100m / 330ft UTP cable, 50 modular jacks, crimping tool
6502001030
Serial connection cables RS 232-cross wired, 6m
6502100100
Serial connection cables RS 232-cross wired, 10m
6502100150
Serial connection cables RS 232-cross wired, 15m
6502100200
Serial connection cables RS 232-cross wired, 20m
6502100250
Serial connection cables RS 232-cross wired, 25m
* These parts are standard included with the delivery of the MasterBus–Combi Interface
Mastervolt can offer a wide range of products for your electrical installation, including an extended program of
components for your MasterBus network. See www.mastervolt.com for a complete overview of all our products.

6 TROUBLE SHOOTING

Contact your local Mastervolt Service Centre if you cannot correct a problem with the aid of the malfunction table
below. See www.mastervolt.com for an extended list of Mastervolt Service Centres.
Failure
No MasterBus activity
is present.
The green LED on
the interface is not
illuminated or blinking.
The connected device
cannot be found.
No communication
between the connected
device and the
MasterBus network.
6
Possible cause
There is no MasterBus powering device
connected or switched on.
The MasterBus–Combi Interface has not
been connected to the serial port.
The MasterBus–Combi Interface has not
been connected to the MasterBus port.
Connected device is switched off.
Error in the wiring.
Wrong connections. The MasterBus cable
shall not be linked to a non-MasterBus
connector like RS232. The serial cable shall
not be linked to the MasterBus connector.
If a setting of the connected device has
been changed, communication between
the MasterBus network and the connected
device may take a few seconds.
Error in the wiring.
No terminating device placed at the ends of
the network.
network.
What to do
Connect and/ or switch on the MasterBus
powering device (like the MasterShunt).
Check serial cable and connections
between the MasterBus–Combi Interface
and the serial port.
Check MasterBus cables and connections.
Switch on connected device
Check the serial cables. You need Cross wired
serial cables (1 to 6), no MasterBus cables.
Check the connections.
Wait for a few seconds.
Check the MasterBus cables and serial cable.
You need Cross wired (1 to 6) serial cables (no
Straight wired cables and no MasterBus cables).
Check if terminating devices are installed on
both ends of the MasterBus network (see
manual of the MasterBus powering device).
Ring networks are not allowed (see manual
of the MasterBus powering device). Check
the connections of the network.
March 2011 / MasterBus–Combi Interface / EN