4 Maintenance and cleaning
4
Maintenance and cleaning
WARNING
The boiler should be maintained by authorised persons
every year.
Annual maintenance cycle is very important for safe operation of
your boiler and to ensure reliable, efficient and long lasting operation
of it.
Contact your service agent for details.
DANGER
Incorrect maintenance and repairs can lead to injury and
material damage.
▪ Never attempt to perform maintenance work or repairs
on the unit yourself.
▪ Contact your service agent.
4.1
To clean the outer surface of the
unit
Clean the outer surface of your boiler with a damp cloth and a little
solvent-free soap.
CAUTION
Sprays, solvents or cleaning agents containing chlorine
can damage the exterior, the fittings or the control unit. Do
not use them for cleaning purposes.
5
Energy saving tips
▪ Operating the unit in central heating ECO mode provides the most
economical central heating operation conditions.
▪ Do not run the boiler in domestic hot water comfort mode.
Domestic hot water comfort mode involves pre- and post-heating,
which is luxury, not necessity.
▪ Close the thermostatic radiator valves when ventilating the rooms.
▪ The largest heat loss occurs through windows and outer doors.
Check windows and doors for air-tightness. Close any blinds at
night.
▪ Do not hide radiators behind large furniture (i.e. couch, desk, etc.).
Minimum 50 cm of clearance must remain, otherwise the heated
air cannot be circulated and the room will not heat up efficiently.
▪ Do not let your room become too hot. Decreasing the room
temperature during the day saves energy.
▪ Have your combi boiler's maintenance performed at least
annually.
▪ Provide your building with sufficient heat insulation.
▪ Thermostatic valves should be used. Each room should be
adjusted according to comfort conditions. For reception rooms,
this is 20°C, living rooms 22°C, kitchens 18°C and bedrooms
18°C.
▪ Prevent radiators from getting covered by curtains.
6
Contact
Contact a local competent service agent if you have any questions
regarding the maintenance and repair of your system. You can find
the contact information of our competent services at www.daikin.com
Operation manual
10
7
Error codes
#
Problem
10-64 Gas valve circuit error Perform reset. If problem repeats,
contact your service agent.
10-65 Gas valve current
Perform reset. If problem repeats,
error
contact your service agent.
11-64 Ignition does not take
Make sure valve on the gas line is
place
opened. Perform reset after third
unsuccessful ignition trial.
11-65 Flame stabilisation
Wait for boiler's ignition trial.
fault
11-66 Flame signal loss in
Perform reset after third
safety time
unsuccessful ignition trial. If problem
repeats, contact your service agent.
11-67 Flame loss during
Temporary error. Wait for boiler to
operation
re-ignite.
12-64 Ion control deviation
Perform reset if needed. If problem
is too big
repeats, contact your service agent.
12-65 Ignition SCOT
Perform reset if needed. If problem
actuators fault does
repeats, contact your service agent.
not take place
12-66 Ion base value
Perform reset. If problem repeats,
exceeds lower factory
contact your service agent.
limit
12-67 Ion base value
Perform reset. If problem repeats,
exceeds upper
contact your service agent.
factory limit
12-68 Ion base value differs
Perform reset if needed. If problem
excessively from
repeats, contact your service agent.
previous value
12-69 Offset adaption at
Boiler continues operation but
limit
contact your service agent.
12-70 Offset adaption not
Boiler continues operation but
executable
contact your service agent.
13-64 Fan speed error
Perform reset if needed. If problem
repeats, contact your service agent.
13-65 Fan speed error
Perform reset. If problem repeats,
contact your service agent.
16-64 Flue temperature
Check flue gas discharge path.
signalise overheating
Perform reset if needed. If problem
repeats, contact your service agent.
1J-64 High limit thermostat
▪ Check the valves of the radiators
signalise overheating
▪ Check the combi boiler water
▪ Perform reset. If problem repeats,
80-01 Return temperature
Perform reset. If problem repeats,
sensor fault
contact your service agent.
81-01 Flow temperature
Perform reset. If problem repeats,
sensor fault
contact your service agent.
81-65 Domestic hot water
Boiler continues operation but solar
solar temperature
sensor is defective. Contact your
sensor fault
service agent.
8A-46 Freeze protection
Unit does not operate if flow
temperature sensor reads value less
than 1°C. Wait until the error code is
removed from the screen.
D2C18ND024A5AA + D2HND012/18A5AA
Solution
in the heating circuit.
pressure. If it is low, fill the heating
circuit with water.
contact your service agent.
Wall-mounted condensing boiler
3P469438-9H – 2018.05