Caution
When the pump is installed outside, we recommend providing
a simple protection against the weather (rain, sun etc.).
Caution
Implement appropriate measures to attenuate the noise
generated by the pump to avoid damage to the environment.
Fastening the pump to the foundation should be effected
exclusively by means of bolts, threads or dowels, in order to
avoid blocking the removal of the motor unit! Make sure that
there is enough space between the fan cover and the wall,
minimum 50 mm. You also need enough space to permit
disassembly of the strainer basket, minimum 210 mm above.
The pump should be installed at water level
or below water level and in a horizontal
position, in order to keep the suction path
as short as possible and to reduce head
loss. The Aqua Plus OKU is self-priming
and should never be installed more than
2 m above water level. Make sure that the
suction line is not leaky, otherwise the pump
will prime insuffi ciently or not at all. We
recommend the installation of check valve
and shut-off valves depending on the type
of pump or unit. The adhesive bonds in the
suction and pressure lines require more
time to cure, allow at least 12 hours before
starting the pump.