QUICK START INSTRUCTIONS
STEP 1 - VERIFY PACKAGE CONTENTS
DISCHARGE
SUCTION
INLET
STEP 2 - VERIFY EXISTING PUMP VOLTAGE
All electrical wiring or service should
115 V
be done by a qualified electrician. You
must match the voltage of our pump to
the existing power supply.
230 V
STEP 3 - HOW TO CHANGE VOLTAGE SELECTOR
This pump is factory wired for 230 volts. To change the voltage to
115 volts follow the steps below:
1. Disconnect the pump from power.
2. Remove cover from back of motor to find voltage selector.
3. Pull selector knob out.
4. Rotate selector knob to correct voltage setting.
5. Push selector knob back in place.
6. Reinstall cover to back of motor.
© 2012,
WAYNE/Scott Fetzer Company.
SWIMMING POOL PUMP
OPERATING INSTRUCTIONS & PARTS MANUAL
MODELS - WIP150 / WIP100 / WIP90 (TITLE 20 COMPLIANT)
(1) PUMP
(1) LID
(1) GASKET
(1) STRAINER
VOLTAGE SELECTOR
For parts, product & service information
visit www.waynepumps.com
STEP 4 - ELECTRIC BONDING
Use solid copper bonding conductor
not smaller than 8 AWG (8.4 mm
STEP 5 - PUMP PLUMBING
Before attempting installation of any swimming pool pump, read and
understand ALL guidelines (ANSI/APSP/ICC-15 2011) regarding suction
and installation. Suction pipe should be as large or larger than discharge
pipe. Avoid using a suction pipe smaller than pump connection.
ANSI/APSP-16 (2011) Certified
No Valves Between
Component Anti-Entrapment
Tee and Main Drains
Cover/Grate or Suction Fitting
Suction Outlet
(Main Drain)
Valves OK Between
Pump and Tee
WARNING – DO NOT attempt installation
of swimming pool pump unless you have read
and understand the following standards, guidelines and regulations:
ANSI/APSP-16 (2011); ANSI/APSP-7 (2006); ANSI/ASME A112.19.17
(2010); ASTM F2387 (2004); Virginia Graeme Baker Pool and Spa Safety
Act (2007); CPSC's publication entitled Guidelines for Entrapment
Hazards; and any successor standards or state law requirements.
DO NOT enter the swimming pool if any drain cover is broken or
missing. Close the swimming pool or spa. Immediately call your
professional to make repairs. Prime pump before attempting to operate.
To prime pumps located above water level, remove strainer cover, fill
strainer body with water then replace cover. If pump and all piping is
located below water level, the pump will self prime.
After pump has been primed, energize motor and open all suction and
discharge line valves. If no flow is observed in five minutes, stop the
motor and re-prime. If the pump fails to operate, check for air leaks.
Refer to troubleshooting section.
After about 10 minutes of operation, check the return fittings for air
bubbles. A continuous flow of air indicates leaks in the suction line.
Locate and correct any leaks immediately.
FOR FURTHER INSTRUCTIONS, SAFETY REQUIREMENTS/
STANDARDS/ REGULATIONS FOR INSTALLATION REFER
TO THE INFORMATION PROVIDED IN THIS MANUAL.
WIP SERIES
SWIMMING POOL PUMP
).
2
At Least
3 Feet
ANSI/APSP-16 (2011) Certified
Component Anti-Entrapment
Cover/Grate or Suction Fitting
Suction Outlet
(Main Drain)
Pump