Connecting the IU0U automatic charger to the exhaust system

Mounting the IU0U automatic charger on the wall
➤ Clip two holders on the left bar and two on the lower right bar (fig. 4,
page 5).
You can move the holders as required.
➤ Screw the mounting bracket (fig. 6 1, page 6) on to the wall by screwing
one screw into each of the four holes.
➤ Press the IU0U automatic charger (fig. 6 2, page 6) on to the mounting
bracket so that the edge on the back of the IU0U automatic charger is
pinched between the wall and the clip on the mounting bracket.
➤ Fasten the IU0U automatic charger by screwing one screw through each
hole in the holders.
8
Connecting the IU0U automatic
charger to the exhaust system
You can connect the IU0U automatic charger to an exhaust system. The
warm exhaust is thereby driven out of the internal chamber.
Proceed as follows (fig. 7, page 6):
➤ Set the exhaust adapter (2) on the front of the charger (1) over the fan, so
that the screws fit into the holes.
➤ Attach the exhaust adapter using the four screws provided.
➤ Connect the hose support (3, not included) to the exhaust adapter.
➤ Connect the exhaust system hose (4) to the hose support.
9
Connecting the IU0U automatic
charger
WARNING!
!
The IU0U automatic charger may only be connected by a qualified
specialist.
The following information is intended for technicians who are famil-
iar with the guidelines and safety precautions to be applied.