45
SC iJust NexGen – Protective Functions
15-Second Protection
If you press and hold the Fire button for more than 15 seconds, the LED indicator light flashes 10 times
and the output cuts off automatically�
Short Circuit Protection
If short circuit occurs before vaping, the indicator light will flash 5 times and the output cuts off
automatically when you start to vape; if short circuit occurs during vaping, the indicator light will flash
3 times�
Low Voltage Protection
If the battery power drops below 3�3 V, the LED Light flashes 40 times and the battery is switched off
automatically�
Resistance Protection/No Vaporizer Head Detected
If the resistance of the device exceeds 3�0 ohm, the LED Light flashes slowly� If the resistance drops
below 0�15 ohm, the device flashes five times� Make sure you use a head that is compatible and
attached correctly�