7
TROUBLESHOOTING
If the product does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
Symptom
Problem
Rotatable
Balance
hood does not
problem.
stay in desired
position.
Arm does not
Balance
stay in desired
problem.
horizontal/
vertical/
diagonal
position
Arm does not
Movement
stay in
problem.
retracted
position.
Poor suction.
Extraction
arm does not
function
properly.
8
SPARE PARTS
The following spare parts are available for the product (refer to
exploded view Fig. VI on page 40).
Article no.
Description
9880020010
Hose 500 mm (20 in.) (5 pieces)
Hose 1650 mm (65 in.)
0692000000
Polyester rope Ø 4 mm (0.16 in.)
0840101030
Bush Ø 203 mm (8 in.)
9823000000
Rotatable hood RotaHood, complete
9823000100
Throat rotatable hood, complete
9823000990
Throat rotatable hood HD, complete
9823003000
Rotatable hood RotaHood HD, complete
9824000010
Hinge set rotatable hood, incl. protection cover
9824000100
Rubber protection cover hood hinge
9
DISPOSAL
After life of the product, dispose it of in accordance with federal,
state or local regulations.
0507291010/260411/A T-Flex/CW
Possible cause
Solution
Too much or not
Adjust friction.
enough friction in
Refer to Fig. IV on
hood hinge.
page 39;
A = vertical
movement;
B = horizontal
movement.
Spring loose.
Tighten spring.
Refer to Fig. V on
page 39;
A = spring.
Too much or not
Adjust friction.
enough friction in
Refer to Fig. V on
arm.
page 39;
B = friction.
Counterweight
Extend the arm
gets stuck.
and retract it
again slowly.
Rope broken.
Replace rope.
Throttle valve
Open throttle
closed.
valve.
Flexible hose(s)
Mount correctly or
torn or loose.
replace.
Bush(es)
Mount correctly or
damaged or loose.
replace.
EN - 13