Télécharger Imprimer la page

Simer A5200 Notice D'utilisation page 11

Publicité

Les langues disponibles

Les langues disponibles

Wiring • Setup
NOTICE: During normal operation, the flashing 'PUMP
STATUS' LED indicates that the pump has run in your
absence.
7. Press and hold 'SYSTEM TEST' button. All LEDs will
light up, pump will run and buzzer will sound.
Release the button and LEDs should go off, pump
should stop, buzzer should stop.
8. The 'BATTERY STATUS' LED indicates the battery
capacity when the A.C. power is off.
A. Continuously ON - the battery voltage is above
10.9 Volts Direct Current (10.9VDC) and
capacity is above 20%.
B. Slow Beep/Slow LED Flash - the battery's
capacity is between 0 and 20%.
LED Display and Control Buttons
NOTICE: When the unit is first plugged in, or when it first receives power from the battery, the 'BATTERY STATUS'
LED will flash for 3 seconds.
NOTICE: To activate any Control Button, press and hold it for 1 second.
C. Fast Beep/Fast LED Flash - the battery is severely
discharged. The battery will continue to charge
(as long as the 115V AC power to the charger is
on) at the rate of .5 AH until the battery's charge
is above 20%.
When the first warning occurs (slow beep/slow flash),
you will have approximately 2 hours (or less) of pump
operation left. The actual time of operation will depend
on the condition of the battery and may be as little as
15 minutes.
9. Connect the Power Supply cable (supplied) to the
Charger/Controller's Power Input jack.
-
+
11

Publicité

loading