Télécharger Imprimer la page

Perel Tools ECM2 Notice D'emploi page 7

Pince ampèremétrique/multimètre

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
4.2 AC current
Range
200A
1000A
Frequency Range : 50Hz to 60Hz
Overload protection : 1200A within 60 seconds. Jaw opening : 2" (5cm)
4.3 Insulation test
With option 500V insulation tester unit.
Range
20MΩ
2000MΩ
4.4 AC Voltage
Range
750V
Input Impedance : ≥ 9MΩ on all ranges
Overload protection : 750V peak or 750Vrms AC on all ranges
4.5 DC voltage
Range
1000V
Input impedance : >9MΩ
Over protection : 250Vrms AC for 200mV range
4.6 Resistance
Range
200Ω
20KΩ
Overload protection : 500V dc or 500Vrms AC on all ranges
4.7 Continuity
Range : 200
Buzzer sound : 50 25
Overload protection : 500VDC / AC rms
5. Accessories
Test leads
Battery
Operating manual
ECM2
Resolution
100mA
1A
Response : Average, Calibrated in rms of sine wave
Resolution
10KΩ
1MΩ
Resolution
1V
Resolution
1V
1000V peak or 1000V rms AC for other ranges
Resolution
0.1Ω
10Ω
Accuracy
±2.0% of rdg ± 5 digits
±3.0% of rdg ± 5 digits
±2.0% of rdg ± 5 digits
Accuracy
±2.0% of rdg ± 2 digits
±4.0% of rdg ± 2 digits
±5.0% of rdg ± 2 digits
±1.0% of rdg ± 4 digits
±0.8% of rdg ± 2 digits
±1.0% of rdg ± 3 digits
±1.0% of rdg ± 1 digit
7
Note
<= 800A
> 800A
Note
≤ 500MΩ
> 500MΩ
Accuracy
Accuracy
Accurcacy
PEREL

Publicité

loading