7.2.2 Configuration of the dip-switches
When the dip-switch rocker (SW) is up it
represents the value 1 (ON) while if it is down
it represents the value 0 (OFF).
Once the configuration cover is opened the dip-
switches will appear as shown in figure.
DIP2
Fig. 20
7.2.3 Protocol configuration
The protocol must be set to NETWORK in case
of versions with digital video encoder (7.2.3
Protocol configuration, page 19).
To set the protocol operate on DIP 3.
The Pan & Tilt can be controlled via various protocols.
PROTOCOL CONFIGURATION (DIP 3)
SW 1
SW 2
SW 3
SW 4
OFF
ON
ON
OFF
Tab. 6
MNVCUCHD_1511_EN
DIP3
DIP1
Configuration
NETWORK
8 Switching on
The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
between 60 and 120 minutes, depending on
conditions.
The unit is switched on by connecting the power
supply.
To switch off the unit disconnect the power.
8.1 First start-up
Make sure that the unit and other
components of the installation are closed so
that it is impossible to come into contact with
live parts.
Make sure that all parts are fastened down
firmly and safely.
19